27
EN
Mounting the wirefeed hoses
Safety
WARNING!
Danger from incorrect operation.
Work that is not carried out correctly can cause serious injury and damage.
► Before putting the unit into service for the first time, read the “Safety rules”
CAUTION!
Risk of injury while the lid is open for maintenance or retooling work to be carried
out.
Work that is not carried out correctly can cause serious injury and damage.
► Ensure that there is no risk of anybody accidentally starting up the VR 1530’s drive
components by pressing the feeder inching button(s) on the control panel, on the VR
1530 itself or on any other system add-ons.
Mounting the
wirefeed hoses
Inserting and fixing the wirefeed hoses
The following description applies to both wirefeed hoses
-
from the unreeling device or bulk wire container to the VR 1530 (1)
-
from the VR 1530 to the VR 1500 (3)
Loosen the knurled thumb-screw (2)
Put the knurled thumb-screw (2) in the middle position
IMPORTANT!
The other positions - (A) and (B) - are for custom wirefeed hoses with spe
-
cially dimensioned wire-guidance nozzles.
Screw in the knurled thumb-screw (2) a short way
Position wirefeed hose (1) or (3) in such a way that the knurled thumb-screw (13) un
-
mistakeably slots into the notch on the brass fitting on the wirefeed hose
Fasten the wirefeed hose with the knurled thumb-screw (2)
(3)
(2)
(1)
(1) / (3)
(2)
(A)
(B)
(2)
1
2
3
4
5