Welding torch becomes very hot
The specification of the welding torch is inadequate
Observe the duty cycle and loading limits
Only on water-cooled systems: Inadequate coolant flow
Check coolant level, coolant flow, for coolant contamination, etc. For further
information refer to the cooling unit operating instructions.
Cause:
Remedy:
Cause:
Remedy:
Poor weld properties
Incorrect welding parameters
Check the settings
Poor ground earth connection
Ensure good contact to workpiece
Inadequate or no protective gas shield
Check the pressure regulator, gas hose, gas solenoid valve, torch gas con-
nection, etc.
Welding torch is leaking
Change the welding torch
Wrong contact tip, or contact tip is worn out
Replace the contact tip
Wrong wire alloy or wrong wire diameter
Check the wire electrode that has been inserted
Wrong wire alloy or wrong wire diameter
Check weldability of the base material
The shielding gas is not suitable for this wire alloy
Use the correct shielding gas
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Displayed service
codes
If an error message that is not described here appears on the displays, proceed as fol-
lows to resolve the problem:
1
Turn the power source mains switch to the "O" position
2
Wait 10 seconds
3
Move the mains switch to the I position
If the error occurs again despite several attempts to eliminate it, or if the troubleshooting
measures listed here are unsuccessful.
1
Make a note of the error message displayed
2
Note down the configuration of the power source
3
Contact our After-Sales Service team with a detailed description of the error
ESr | 20
The selected cooling unit is not compatible with the power source
Connect compatible cooling unit
Cause:
Remedy:
98
Summary of Contents for TransSteel 2700c
Page 2: ......
Page 18: ...18...
Page 19: ...General information 19...
Page 20: ...20...
Page 26: ...VRD is active again The output voltage is limited to 35 V once more 26...
Page 27: ...Control elements and connections 27...
Page 28: ...28...
Page 37: ...Installation and commissioning 37...
Page 38: ...38...
Page 62: ...62...
Page 63: ...Welding 63...
Page 64: ...64...
Page 78: ...Number 2 Number 3 Number 4 Number 5 78...
Page 79: ...Setup settings 79...
Page 80: ...80...
Page 91: ...10 Fit the gas nozzle back onto the welding torch 91 EN...
Page 93: ...Troubleshooting and maintenance 93...
Page 94: ...94...