Level
Increase in arc size before function is triggered
2
Small increase required
1
Very small increase required
0
TIG Comfort Stop deactivated (factory setting)
Pulsing fre-
quency para-
meter
The frequency parameter is only available on the TP 2500/3500 TIG power source and is
used to set the frequency of the pulsed arc.
The pulsed arc frequency is one of the most important criterion for the TIG pulsed arc
welding properties.
Level
Pulse frequency
5
60 Hz
4
10 Hz
3
4 Hz
2
2 Hz
1
1 Hz (factory setting)
0
0.5 Hz
32