EN-US
Setup Menu 2nd Level
Setup Menu 2nd
Level Parameters
Parameter
Description
Range
Unit
Software version
The complete version number of the current soft-
ware is divided across several displays and can
be viewed by turning the selection dial
Automatic shutdown (time Shut down)
If the device is not used or operated within a set
period of time, it automatically switches into
Standby mode
Pressing a button on the control panel switches off
Standby mode - the device is now ready for weld-
ing
Factory setting: OFF
5 - 60
OFF
Minutes
Fuse
To display/set the fuse being used
Factory setting:
-
For grid voltage 230 V = 16 A
-
For grid voltage 120 V = 20 A
If a fuse is set on the power source, the power
source will limit the current drawn from the grid,
which prevents an immediate tripping of the power
circuit breaker
At
230 V
10 / 13 /
16 / OFF
At
120 V:
15 / 16 /
20 / OFF
Ampere
Relationship between set fuse and pre-heating current:
Grid voltage
Set
fuse
Pre-heating current
Duty cycle
230 V
10 A
180 A
35%
13 A
180 A
35%
16 A
180 A
35%
OFF
180 A
35%
120 V
15 A
140 A
35%
16 A
140 A
35%
20 A
170 A
35%
OFF
170 A
35%