![Fronius TransArc 150 Leybold Operating Instructions/Spare Parts List Download Page 15](http://html1.mh-extra.com/html/fronius/transarc-150-leybold/transarc-150-leybold_operating-instructions-spare-parts-list_2339302015.webp)
15
Change the PWM pcb.
Order.no.: 380V - 4.070.169
415V - 4.070.172
Start-up ramp time: 3 jumpers
Designation
AZ0 - AZ2
000
0.25 s
001
0.5 s
010
0.75 s
011
1.0 s
100
1.25 s
101
1.5 s
110
1.75 s
111
2 s
Start-up ramp voltage: 3 jumpers
Designation
AS0 - AS2
000
7.5 V
001
15.0 V
010
22.5 V
011
30 V
100
37.5 V
101
45 V
110
52.5 V
111
60 V
Fig. 4
3 KOMPONENTS HAVE TO BE CHANGED
Change the bridge on the STP4 to 380V or 415V
The transformer STPSP must be soldered to the right connec-
tions
380V: middle connection of transformer - two wires
415V: end connection of transformer - one wire
Attention!
Before starting of the power source you have to
check the output voltages on the STPSP X14 / X15,
4 x 9,6V +/- 10%.
If this voltages are not allright the power module can be
destrojed.
CHANGING OF MAINS VOLTAGE RANGE TO
380 / 415V