Connecting the mains cable
General
If no mains cable is connected, a mains cable that is suitable for the connection voltage
must be fitted before commissioning.
A universal strain-relief device for cable diameters from 14 - 16 mm (0.55 - 0.63 in.) is fitted
to the power source.
Strain-relief devices for other cable cross-sections must be designed accordingly.
Stipulated mains
cables
*
Cable type for USA / Canada: Extra-hard usage
AWG =
A
merican
w
ire
g
auge
Select a strain-relief device based on the cable required.
Connecting the
mains cable -
general
IMPORTANT!
The ground conductor should be approx. 30 mm (1.18 in.) longer than the
phase conductors.
Power source
Mains voltage
Cable cross-section
USA / Canada *
Europe
TPS 320i nc
3 x 400 V
AWG 12
4G 2.5 mm²
3 x 460 V
AWG 14
4G 2.5 mm²
TPS 400i nc
3 x 400 V
AWG 10
4G 4.0 mm²
3 x 460 V
AWG 12
4G 4.0 mm²
TPS 500i nc
3 x 400 V
AWG 8
4G 4.0 mm²
3 x 460 V
AWG 10
4G 4.0 mm²
CAUTION!
Risk of injury and material damage due to short circuits.
Short circuits can occur between the phase conductors or between the phase
conductors and the ground conductor unless ferrules are used.
Fit ferrules to all phase conductors in an exposed mains cable as well as the
ground conductor.
NOTE!
Mains cables must be connected to devices in compliance with national
standards and guidelines and the work must be carried out by a qualified person.
1
2
Summary of Contents for TPS 320i
Page 2: ...0 ...
Page 4: ...2 ...
Page 8: ...6 ...
Page 21: ...General information ...
Page 22: ......
Page 27: ...Controls connections and mechani cal components ...
Page 28: ......
Page 32: ...30 ...
Page 33: ...Operating concept ...
Page 34: ......
Page 39: ...Installation and commissioning ...
Page 40: ......
Page 45: ...43 EN 3 4 5 3 4 5 9 8 7 6 2 6 ...
Page 51: ...Welding ...
Page 52: ......
Page 76: ...74 ...
Page 77: ...Defaults ...
Page 78: ......
Page 81: ...Troubleshooting and maintenance ...
Page 82: ......
Page 87: ...Appendix ...
Page 88: ......