16
Safety measures
in normal opera-
tion
Special regulations apply in rooms at risk of fire or explosion
-
Observe relevant national and international regulations.
Use internal directives and checks to ensure that the workplace environment
is always clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protec-
tion shown on the rating plate.
When setting up the device, ensure there is an all-round clearance of 0.5 m (1
ft. 7.69 in.) to ensure that cooling air can flow in and escape unhindered.
When transporting the device, observe the relevant national and local guide-
lines and accident prevention regulations. This applies especially to guidelines
regarding the risks arising during transport.
Before transporting the device, allow coolant to drain completely and detach
the following components:
-
Wire-feed unit
-
Wirespool
-
Shielding gas cylinder
After transporting the device, the device must be visually inspected for dam-
age before commissioning. Any damage must be repaired by trained service
technicians before commissioning the device.
Only operate the device if all safety devices are fully functional. If the safety
devices are not fully functional, there is a risk of
-
injury or death to the operator or a third party,
-
damage to the device and other material assets belonging to the operator,
-
inefficient operation of the device.
Any safety devices that are not functioning properly must be repaired before
switching on the device.
Never bypass or disable safety devices.
Before switching on the device, ensure that no one is likely to be endangered.
Check the device at least once a week for obvious damage and proper func-
tioning of safety devices.
Always fasten the shielding gas cylinder securely and remove it beforehand if
the device is to be transported by crane.
Only the manufacturer's original coolant is suitable for use with our devices
due to its properties (electrical conductibility, anti-freeze agent, material com-
patibility, flammability, etc.).
Only use suitable original coolant from the manufacturer.
Do not mix the manufacturer's original coolant with other coolants.
The manufacturer accepts no liability for damage resulting from the use of a
different coolant. In addition, all warranty claims will be forfeited.
The coolant can ignite under certain conditions. Transport the coolant only in
its original, sealed containers and keep well away from any sources of ignition.
Used coolant must be disposed of properly in accordance with the relevant na-
tional and international regulations. The coolant safety data sheet may be ob-
tained from your service centre or downloaded from the manufacturer's
website.
Check the coolant level before starting to weld, while the system is still cool.
Summary of Contents for TPS 320i
Page 2: ...0 ...
Page 4: ...2 ...
Page 8: ...6 ...
Page 21: ...General information ...
Page 22: ......
Page 27: ...Controls connections and mechani cal components ...
Page 28: ......
Page 32: ...30 ...
Page 33: ...Operating concept ...
Page 34: ......
Page 39: ...Installation and commissioning ...
Page 40: ......
Page 45: ...43 EN 3 4 5 3 4 5 9 8 7 6 2 6 ...
Page 51: ...Welding ...
Page 52: ......
Page 76: ...74 ...
Page 77: ...Defaults ...
Page 78: ......
Page 81: ...Troubleshooting and maintenance ...
Page 82: ......
Page 87: ...Appendix ...
Page 88: ......