Care, maintenance and disposal
General
The cleaning device generally needs no maintenance. However, to keep the cleaning de-
vice in good working condition for years to come, several points on care and maintenance
must be observed.
Before each start-
up
-
Check the cleaning brushes on the brush head and replace worn brushes
-
Empty the cleaning device spatter tray
-
If fitted, empty the wire cutter tray
-
Carry out a general visual inspection of the cleaning device and wire cutter
Daily
-
Remove any dirt deposits from device
Every 6 months
Open the device and check the pneumatic valves for:
-
leaks
-
the secure seating of all screws
-
the secure seating of all screw joints on the pneumatic valves
If necessary
Open the device and
-
clean the inside of the device using dry reduced compressed air
-
lightly oil the lifting device cylinder guides
Changing the end
brushes (stand-
ard brush head
only)
Remove the protective covering from the cleaning device
5
6
Fit the protective covering to the cleaning device in its original position
1
2
3
4
Summary of Contents for Robacta Reamer
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 15: ...General...
Page 16: ......
Page 21: ...Controls connections and mechani cal components...
Page 22: ......
Page 26: ...26...
Page 27: ...Installation and commissioning...
Page 28: ......
Page 44: ...44 NOTE The wire cutter must be controlled electrically by the robot control...
Page 52: ...52...
Page 53: ...Care maintenance and disposal...
Page 54: ......
Page 60: ...60...
Page 61: ...Troubleshooting...
Page 62: ......
Page 66: ...66...
Page 67: ...Technical data...
Page 68: ......
Page 70: ...70...
Page 71: ...Appendix...
Page 72: ...72 Spare parts list Robacta Reamer brush head for al uminium applications...
Page 74: ...74 Circuit diagrams Robacta Reamer brush head for al uminium applications...
Page 76: ...76 Pneumatics diagram of Robacta Reamer brush head for aluminium applications...
Page 78: ...78...
Page 79: ...79...