Troubleshooting
Errors in the Pro-
gram Sequence
Parting agent is not injected
Parting agent container is full
Injection quantity too low
Extend injection time
Intake filter of the parting agent hose in the parting agent container is con-
taminated
Clean the suction filter of the parting agent hose with compressed air (for
more information, see section
Starting Up the Parting Agent Atomizer
No signal from robot
Check robot program
Parting-agent injection nozzle blocked
Clean the parting-agent injection nozzle
Notify the service team (parting-agent injection nozzle needs replacing)
Vacuum pump defective
Contact service team (vacuum pump needs replacing)
Solenoid valve has mechanical fault
Contact service team (solenoid valve needs replacing)
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Welding torch has been poorly cleaned or is damaged
Position of the cleaning motor incorrectly set
Correctly set the position of the cleaning motor
Gas nozzle is clamped in incorrect position
Adjust the gas nozzle clamping device
Cleaning cutter does not fit the welding torch geometry
Fit a correct cleaning cutter
Cleaning cutter worn
Replace cleaning cutter
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
63
EN-US
Summary of Contents for Robacta Reamer X-Line J
Page 2: ......
Page 11: ...General 11 ...
Page 12: ...12 ...
Page 15: ...Warning before the device switches on automatically 15 EN US ...
Page 18: ...18 ...
Page 19: ...Operating controls connections and mechanical components 19 ...
Page 20: ...20 ...
Page 25: ...Installation and Startup 25 ...
Page 26: ...26 ...
Page 53: ...Service maintenance and disposal 53 ...
Page 54: ...54 ...
Page 58: ...Disposal Materials should be disposed of according to valid national and regional rules 58 ...
Page 59: ...Troubleshooting 59 ...
Page 60: ...60 ...
Page 65: ...Technical data 65 ...
Page 66: ...66 ...
Page 68: ...68 ...
Page 69: ...Appendix 69 ...
Page 73: ...73 ...
Page 74: ...74 ...
Page 75: ...75 ...