Parameters of standard characteristics
Ignition
Feeder creep speed
Wire feed speed [m/min] before welding begins (0 - currently set wire feed speed)
Ignition current
Strength of ignition current [A] set when welding begins. The ignition current depends on
the filler metal and wire diameter.
-
In the case of low ignition current, the welding wire is not sufficiently preheated or
burned
-
In the case of high ignition current, the filler wire is excessively preheated or burned
Arc (static)
Wire feed speed
The wire feed speed [m/min] regulated via a pulse generator guarantees a controlled
speed value on the feed rollers.
Effects of an excessively high wire feed speed:
-
arc too short
-
The wire electrode is not sufficiently melted - heavy spatter due to wire electrode pen-
etrating the welding material
Effects of an excessively low wirefeed speed:
-
arc too long
-
scoring may appear around the weld seam
-
Welding wire may weld fast to the contact tip
Base current
Even at low currents, the base current [A] guarantees a stable arc in the dip transfer arc
burning phase.
Effects of an excessively high base current:
-
wire electrode welded on too hard
-
large drops form
Effects of an excessively low base current:
-
ionisation of the arc section too low
-
arc breaks in the base current phase
Voltage command value
This parameter gives the voltage command value in [V] for the arc.
Effects of excessively high voltage:
-
arc too long
-
scoring may appear around the weld seam
-
wire electrode may weld fast to the contact tube
-
low short-circuit frequency
Ignition current time
The length of time [ms] that the set ignition current is active when welding begins
0
=
no ignition current
40
=
max. duration for ignition current
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...