27
EN-US
IMPORTANT!
The time must be set correctly in order for the logging function to work prop-
erly.
Relay
Activate Relay, Relay Settings, Relay Test
* only shown if the 'E-manager' function has been activated under "Relay Mode."
Relay Mode
For selection of the various functions of the potential-free switching contact in the data
communications area:
-
Alarm function
-
Active output
-
Energy manager
Relay test
Functional test to check if the potential-free switching contact works
Switch on point
(only if "Energy manager" function is activated )
for setting the effective power limit from which the potential-free switching contact will be
switched on
Switch off point
(only if the "Energy manager" function is activated)
for setting the effective power limit from which the potential-free switching contact will be
switched off
Setting range
Relay Mode / Relay Test / Switch on Point* / Switch off Point*
Setting range
ALL / Permanent / OFF / ON / E-manager
Factory setting
ALL
Alarm function:
Permanent /
ALL:
Switches the potential-free switching contacts for continual and tem-
porary service codes (e.g., brief interruption of grid power feed opera-
tion, a service code occurs a set number of times per day – can be set
in the "BASIC" menu)
Active output:
ON:
The potential-free switching contact NO is switched on at all times
while the inverter is operating (as long as the display lights up or ap-
pears)
OFF:
The potential-free switching contact NO is switched off
Energy manager:
E-manager:
You can find additional information on the "Energy manager" function
in the "Energy Manager" section below
Factory setting
1000 W
Setting range
Switch off point – max. power rating of the inverter / W / kW
Factory setting
500
Setting range
0 – switch on point / W / kW