25
EN-US
DATCOM
Check of a data communication, entry of the inverter number, DATCOM night mode, pro-
tocol settings
Status
Displays data communication available via Solar Net or an error that occurred in data com-
munication
Inverter Number
Number setting (address) of the inverter in a setup where multiple solar inverters are linked
together
Protocol type
Defines the communication protocol used to transmit data:
* The protocol type Interface Protocol only works without the Datamanager card. Available
Datamanager cards must be removed from the inverter.
USB
Value settings when using a USB stick
Safely remove hardware
To remove a USB stick from the USB A socket on the data communication rack without
losing data.
The USB stick can be removed:
-
when OK is displayed
-
when the "Data Transfer" LED is no longer flashing or illuminated
Software update
For updating inverter software using a USB stick.
IMPORTANT!
Firmware may only be updated by Fronius Service Technicians or Fronius
Service Partners.
***
WiFi Access Point
[not available]
Is displayed, when no system monitoring is present at the invert-
er.
Setting range
Status / Inverter number / Protocol type
Setting range
00 – 99 (00 = 100 inverter)
Factory setting
01
IMPORTANT!
Each inverter must be assigned its own address when using multiple invert-
ers in a data communications system.
Setting range
Solar Net / Interface Protocol *
Factory setting
Solar Net
Setting range
Safely remove hardware / software update / logging interval