Malfunction of the torch trigger
Faulty plug connections between the welding torch and the power source
Establish correct plug connections/send power source or welding torch to
service team
Soiling between torch trigger and torch trigger housing
Remove soiling
Faulty control line
Notify service provider
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Porosity of weld seam
Spattering in the gas nozzle, causing inadequate gas shield for weld seam
Remove welding spatter
Holes in gas hose or imprecise gas hose connection
Replace gas hose
O-ring at central connector is cut or faulty
Replace O-ring
Moisture/condensate in the gas line
Dry gas line
Gas flow too strong or weak
Correct gas flow
Inadequate quantity of gas at the start or end of welding
Increase gas pre-flow and gas post-flow
Rusted or poor quality wire electrode
Use high-quality wire electrode without soiling
Applies to gas-cooled welding torches: Gas leakage with non-isolated inner
liners
For gas-cooled welding torches, only use isolated inner liners
Too much parting agent applied
Remove excess parting agent/apply less parting agent
Extraction too strong
Reduce extraction
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy: