Safety symbols
on the rating
plate

The KD Supply 2500 has safety symbols on the rating plate. The safety symbols must
NOT be removed or painted over. The symbols warn against operating the equipment in-
correctly, which can cause serious injury and damage.

  Welding is dangerous. The following basic requirements must be met:

-

Welders must be sufficiently qualified

-

Suitable protective equipment

-

Keep all persons not involved in the welding process at a safe distance

  Do not use the functions described here until you have read and completely

understood all of the following documents:
-

these Operating Instructions

-

all the Operating Instructions for the system components, especially
the safety regulations

Warning notices
affixed to the ma-
chine

Machines destined for the USA have additional warning notices. The warning notices
must NOT be removed or painted over.

5

EN

Summary of Contents for KD Supply 2500

Page 1: ...prints on elemental chlorine free paper ECF sourced from certified sustainable forests FSC Perfect Charging Perfect Welding Solar Energy KD Supply 2500 EN Operating instructions 42 0426 0049 EN 002 0...

Page 2: ......

Page 3: ...he base of the trolley 8 Connecting the KD Supply 2500 to the cooling unit and power source 9 Safety 9 Connecting the KD Supply 2500 to the cooling unit and power source 9 Establishing a LocalNet conn...

Page 4: ...Indicates immediate danger If not avoided death or serious injury will result WARNING Indicates a potentially hazardous situation If not avoided death or serious injury may result CAUTION Indicates a...

Page 5: ...t be sufficiently qualified Suitable protective equipment Keep all persons not involved in the welding process at a safe distance Do not use the functions described here until you have read and comple...

Page 6: ...US machine with additional warning notices 6...

Page 7: ...and understand this document in full Read and understand all safety rules and user documentation for this device and all system components KD Supply 2500 front 1 2 1 LocalNet X9 1 interface Standard...

Page 8: ...f a cooling unit is present fit it right at the bottom and place the KD Supply on top of it Fitting the KD Supply 2500 to the base of the trolley 1 If there are no fastening brackets on the trolley At...

Page 9: ...plug 3 Remove protective cover from the un derside of the power source 4 Firmly press four M5 hexagonal nuts supplied with the KD Supply 2500 from the inside into the hexagonal re cesses 1 in the fast...

Page 10: ...sonal injury and damage to property When positioning the KD Supply 2500 ensure that the cables are not kinked 15 Carefully place power source on KD Supply 2500 16 Using two Extrude Tite screws fasten...

Page 11: ...the interconnect ing hosepack to the KD Supply 2500 a LocalNet X9 2 interface front or b LocalNet X9 3 interface rear Commissioning Power for the KD Supply 2500 is supplied by the power source 1 Conne...

Page 12: ...ing the device use a suitable measuring instrument to check that electric ally charged components such as capacitors have been discharged Every start up Check welding torch interconnecting hosepack an...

Page 13: ...voltage 230 460 V Mains frequency 50 60 Hz Primary current I1 2 4 1 3 A Secondary voltage U2 55 V Secondary current I2 4 A Protection IP 23 Measurements l x w x h 625 x 240 x 225 mm 24 61 x 9 45 x 8...

Page 14: ...14...

Page 15: ...15 EN...