10
Carefully place the KD Supply 2500 on the cooling unit
11
Using two „Extrude-Tite“ screws, fasten the KD Supply to the fastening bars (2) on
the front and back of the cooling unit
12
Position the power source over the KD Supply 2500 using a suitable hoisting device
13
Pull the power source connector as far as possible through the opening on the un-
derside of the power source
14
Make connection between power source and cooling unit
CAUTION!
Risk of short circuit from kinked or damaged cables.
This can result in serious personal injury and damage to property.
▶
When positioning the KD Supply 2500, ensure that the cables are not kinked.
15
Carefully place power source on KD Supply 2500
16
Using two „Extrude-Tite“ screws, fasten the power supply to the fastening bars (1) on
the front and back of the KD Supply 2500.
CAUTION!
Danger from machines falling or toppling over.
This can result in serious personal injury and damage to property.
▶
Ensure that all screw connections are secure.
Establishing a
LocalNet connec-
tion between the
KD Supply 2500
and the power
source
1
Connect the power source and the KD
Supply 2500 using the LocalNet cable
supplied with the KD Supply 2500:
-
Power source: LocalNet interface
-
KD Supply 2500: LocalNet X9.1 inter-
face (front)
10