59
EN
Technical data
General
The cooling capacity of a cooling unit depends on
-
Ambient temperature
-
Delivery head
-
Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
FK 5000, FK 5000
MV
* Optional
FK 5000
FK 5000 MV
Mains voltage
400 V AC
200-230/400-480 V AC
Mains voltage tolerance
-10% / +10%
-10% / +10%
Mains frequency
50 / 60 Hz
50 / 60 Hz
Current input
0.6 / 0.7 A
0.6 / 1.4 A
Cooling power at
Q = 1 l/min + 25 °C (77 °F)
Q = 1l / min + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
1000 W
800 W
1500 W
1000 W
1000 W
800 W
1500 W
1000 W
Max. delivery head
35 m
114 ft. 9.95 in.
35 m
114 ft. 9.95 in.
Max. delivery rate
3.5 l/min
0.92 gal./min
3.5 l/min
0.92 gal./min
Max. pump pressure
4.2 bar
60.89 psi
4.2 bar
60.89 psi
Pump
Centrifugal pump
Centrifugal pump
Pump service life
approx. 10,000 hrs
approx. 10,000 hrs
Coolant capacity
6 l
1.59 gal.
6 l
1.59 gal.
Protection class
IP 23
IP 23
Dimensions l/w/h
710/300/230 mm
27.95/11.81/9.06 in.
710/300/230 mm
27.95/11.81/9.06 in.
Weight (without coolant)
13.6 kg
29.98 Ib.
16 kg
35.27 lb.
Flow monitoring*
Sensor
error below 0.7 l/min
(0.18 gal./min)
Sensor
error below 0.7 l/min
(0.18 gal./min)
Coolant temperature monitoring*
Error above 70 °C
(158 °F)
Error above 70 °C (158
°F)
Mark of conformity
CE
CE, CSA
Summary of Contents for FK 5000
Page 2: ...2...
Page 4: ...4...
Page 18: ...18...
Page 19: ...General...
Page 20: ......
Page 25: ...Connections and mechanical compo nents...
Page 26: ......
Page 28: ...28...
Page 29: ...Installation and commissioning...
Page 30: ......
Page 35: ...35 EN 1 2 1 3 3 2 4 5 6 1 4...
Page 40: ...40...
Page 41: ...Troubleshooting...
Page 42: ......
Page 47: ...Care maintenance and disposal...
Page 48: ......
Page 56: ...56...
Page 57: ...Technical data...
Page 58: ......