![Fronius Eco 25.0-3-S Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/fronius/eco-25-0-3-s/eco-25-0-3-s_operating-instructions-manual_2339161017.webp)
17
EN
Fronius Datamanager 2.0
Controls, connec
-
tions and dis
-
plays on the
Fronius Dataman
-
ager 2.0
No. Function
(1) IP switch
For switching the IP address:
Switch position
A
Default IP address with opening of the WLAN access point
Fronius Datamanager 2.0 uses the set IP address 169.254.0.180 to establish a
direct connection to a PC via LAN.
Setting the IP switch to position A also opens an access point to enable a direct
WLAN connection to the Fronius Datamanager 2.0.
Access data for this access point:
Network name: FRONIUS_240.XXXXXX
Code: 12345678
Access to the Fronius Datamanager 2.0 is possible:
-
Using the DNS name "http://datamanager"
-
Using the IP address 169.254.0.180 for the LAN interface
-
Using the IP address 192.168.250.181 for the WLAN access point
Switch position
B
Assigned IP address
The Fronius Datamanager 2.0 uses an assigned IP address (factory setting dy
-
namic (DHCP))
The IP address can be set on the Fronius Datamanager 2.0 website.
(5)
(1)
(6)
(7)
(10)
(8)
(9)
(4)
(2)
(3)
Summary of Contents for Eco 25.0-3-S