16
Installing plug-in cards into inverters
General
Please see the operating instructions for the respective inverter for information regarding
plug-in card installation.
Please note the safety and warning information in your inverter’s operating instructions.
Safety
WARNING!
An electric shock can be fatal. Danger from grid voltage and DC volt-
age from solar modules.
-
The connection area should only be opened by a licensed electrician.
-
The separate power stage set area should only be disconnected from the
connection area after first being disconnected from the grid power.
-
The separate power stage set area should only be opened by Fronius-trained
service personnel.
Before making any connections, make sure that the AC and DC sides are discon-
nected from the inverter, e.g.:
-
Switch off the AC automatic circuit breaker for the inverter
-
Cover solar modules
Please observe the 5 safety rules.
WARNING!
An electric shock can be fatal. Danger from residual voltage from ca-
pacitors.
You must wait until the capacitors have discharged.
NOTE!
Follow general ESD precautions when handling plug-in cards.
Summary of Contents for DATCOM Compact
Page 2: ...2...
Page 4: ...4...
Page 22: ...22...
Page 24: ...24...
Page 42: ...42...
Page 44: ...44...
Page 62: ...62...
Page 64: ...64...
Page 65: ...65 RU DATCOM Fronius DATCOM CD www fronius com Fronius DATCOM...
Page 66: ...66 Fronius DATCOM DATCOM Fronius DATCOM Fronius...
Page 70: ...70 1 2 Sensor Card DATCOM 3 4 5 IN 6 OUT DATCOM Datalogger pro Box 5 6 DATCOM 1 2 3 4 5 6...
Page 78: ...78 Fronius 5...
Page 84: ...84 Fronius Fronius www fronius com solar warranty Fronius www solarweb com...
Page 85: ...85 RU...