30
AC & DC = Copper Wires (Cu)
Field Wiring with the following wire & wire combinations possible
Select appropriate cable cross-sections according to the actual device output! Do not combine copper and alu
-
minum cables together in a single terminal.
AWG
solid
AWG
stran
-
ded
AWG
stranded / solid
AWG
solid / solid
AWG
stranded / stranded
4
2)
6
2)
6/6
4)
6/12
2)
6/14
2)
6/16
3)
8
2)
8
1)
8/10
1)
8/12
1)
8/14
1)
8/12
2)
8/10
2)
8/12
1)
8/14
1)
8/16
3)
10
2)
10
1)
10/10
1)
10/12
1)
10/14
1)
10/10
1)
10/12
1)
10/14
1)
10/16
3)
12
2)
12
1)
12/10
1)
12/12
1)
12/14
1)
12/16
1)
12/10
1)
12/12
1)
12/14
1)
12/16
1)
14
2)
14
1)
14/10
1)
14/12
1)
14/14
1)
14/16
1)
14/10
1)
14/12
1)
14/14
1)
14/16
1)
16
3)
16
3)
16/14
1)
16/16
1)
16/10
3)
16/12
1)
16/14
1)
16/16
1)
AC & DC = Aluminium Wires (Al)
Field Wiring with the following wire & wire combinations possible
Select appropriate cable cross-sections according to the actual device output!
Do not combine copper and
aluminum cables together in a single terminal.
AWG
solid
AWG
stran
-
ded
AWG
stranded / solid
AWG
solid / solid
AWG
stranded / stranded
4
2)
6
2)
6
4)
6/12
2)
6/14
2)
6/16
5)
8
2)
8
2)
8/10
2)
8/12
2)
8/14
2)
8/12
2)
8/10
2)
8/12
2)
8/14
2)
8/16
5)
10
2)
10
2)
10/10
2)
10/12
2)
10/14
2)
10/10
2)
10/12
2)
10/14
2)
10/16
5)
12
2)
12
2)
12/10
2)
12/12
2)
12/14
2)
12/10
2)
12/12
2)
12/14
2)
12/16
2)
14
2)
14
2)
14/10
2)
14/12
2)
14/14
2)
14/16
2)
14/10
2)
14/12
2)
14/14
2)
14/16
2)
16
5)
16
5)
16/14
2)
16/16
2)
16/10
5)
16/12
2)
16/14
2)
16/16
2)
1)
tested and evaluated according UL
2)
not evaluated according UL, connection to the terminal is possible
3)
only with ferrule
4)
stranded PV (ZKLA) or Use -2 wire
5)
not evaluated according UL, connection to the terminal is possible; The use of ferrules is mandatory for
all AWG 16. The disconnect is technically rated for AWG 16 with ferrules but it is not recommended. If
it is used please insure it is correctly installed. Fronius is not responsible for improper installation.
Summary of Contents for 10.0-3 208
Page 2: ...2...
Page 23: ...23 1 1 1 1 ON OFF Lock 1 2 3 lb 4...
Page 24: ...24 1 1 1 NO NEMA ENCLOSURE TYPE 1 2 Al St 0 2 0 3 in 6 8 mm 3...
Page 27: ...27 1 2...
Page 35: ...35...
Page 37: ...37 Installing Datamanager 2 0 1 1 1 1 1 1 2 1 3 TX20 10 6 lbf in 1 2 Nm 1 2 4 5...
Page 38: ...38 DATCOM Connection 1 1 1 1 1 2 3 4...
Page 39: ...39 1 1 1 5 22 lbf in 2 5 Nm 6 7...
Page 41: ...41 Operation 1 1 4 3 in 1 ON OFF Lock 22 1 lbf in 2 5 Nm 2...
Page 42: ...42 1 1 1 1 3 4 5 6...
Page 47: ...47 Firmware Update 5 4 4 USB 3 1 2 2...
Page 49: ...49...
Page 50: ...50...