168230.01EN_Version03
FROMM
It is forbidden to duplicate this manual or parts of it in any way or any form without written permission of the author © 2006
13
PRINTER OUTPUT PROTOCOL
RS232 output : 1 startbit, 8 databits, 1 stopbit.
Baudrate : selectable 1200 - 19200 in set-up item 2.4b (bAUd)
DTR time-out : 2 seconds see error 07
This protocol only is valid if the automatic print function in 2.4d (AutoPr) is switched off. The information is
send after pressing the PRINT button.
In set-up item 2.4f (Prt Ln) can be given in a number which is defined by the numbers in this list. One or
more lines can be selected by adding the value of the wanted line(s).
1=
Id. : iiiii (code number)
2=
Seq. :sss (sequence number)
4=
Gross: gggg.gg {Unit} (gross weight)
8=
Net : nnnn.nn {Unit} (net weight)
16=
Tare : tttt.tt {Unit} (tare weight)
32=
P.WGT: pp.pppp {Unit} (piece weight)
64=
Count: cccccc (counted numbers)
128= Time and date of the FH190 printer (activates the clock of the FH190 printer)
256= hh:mm da-mo-year (hour : minutes day : month : year)
512= Total sss: aaaa.aa {Unit} (accumulator with number of weighings and totalweight)
1024= --------------------
2048-32768 = not used
Example: printing the Id. number with Gross, Net and Tare weight, give in 29.
PRINTER OUTPUT PROTOCOL