5.3 Solar
5.3.1 Solar - Status
System menu
Solar
Collector temperature
80°C
Display of the current temperature at the solar collector.
Solar temperature buffer tank bottom
43°C
Display of the current temperature at the solar collector in the buffer tank.
Actual power from solar heat meter [kW]
0.00
Display of the current output which is generated by the solar collector. The calculation of the output is only
performed either when a per litre output of the collector pump has been set or an external volume pulse trans‐
mitter is used. In order to perform the calculation more precisely, the use of a collector return feed sensor is
recommended.
Flow through [l/h]
0l
Prerequisite: External volume pulse transmitter installed
Display of the water quantity currently being pumped through the solar collector.
Todays yield [kWh]
0
Display of the heat quantity that has been supplied by the solar panel system today.
Total yield [kWh]
0
Display of the heat quantity which has been supplied by the solar panel system since activation of the heat
meter.
DHW tank bottom temperature
55°C
Current temperature in the area of the reference sensor of the solar panel system.
5
Menu overview and parameters
Solar
22