![Fröling TI 350 Operating Instructions Manual Download Page 64](http://html1.mh-extra.com/html/froling-0/ti-350/ti-350_operating-instructions-manual_2338785064.webp)
Cleaning the area under the moving grate
❒ Undo the six captive screws (A) and remove the cover plate
❒ Remove the thermal insulation
➥ If necessary, cut out the thermal insulation
❒ Loosen the screws on the sensor and take out the sensor
❒ Loosen the nuts on the cleaning cover
❒ Check the area under the moving grate and ash rakes for deposits. Clean where
necessary
❒ Check the grate, grate shafts and grate bearings for wear and deformation
➥ Replace components wherever necessary
❒ Check the grate drive for dirt and deposits and ensure it operates smoothly
❒ Check the seal on the cleaning cover
5
Servicing the system
Maintenance work by the operator
64