4.9.1 Emptying ash
Recommendation: Do not remove the ash in the combustion chamber each time you heat
up the boiler, only when the middle row of holes in the cladding plates is no longer visible.
This protects the combustion chamber and makes the heating-up process more efficient.
Carry out all other cleaning work described in the Cleaning section in the same way.
r
Open the insulated door and the pre-heating chamber door
r
Scrape the ash from the fuel loading chamber into the combustion chamber using the
furnace tool
r
Open the combustion chamber door
r
Remove the ash using the rounded ash shovel
r
Push the ash forwards out of the lower channel of the combustion chamber into the
ash drawer provided using the furnace tool
r
Shovel the ash into container provided
Ä
Fire-proof container with cover!
4.9.2 Cleaning the grating
r
Open the insulated door and the fuel loading chamber door
r
Remove the two-part grating
r
Remove ash deposits under the grating to ensure proper intake of secondary air.
Ä
Tip: Use an ash vacuum!