![Frog Pool Frog Twin Instruction Manual Download Page 8](http://html1.mh-extra.com/html/frog/pool-frog-twin/pool-frog-twin_instruction-manual_2338614008.webp)
8
To prevent damage to heaters or filters,
see your dealer about installing a
corrosion resistant check valve
which
will reduce the back flow of chlorine
gas when the Cyclers are turned off.
Do NOT install
POOL FROG Twin
Cyclers off-line.
Allow a minimum of 12” above and on each
side of POOL FROG Twin Cyclers to ensure
room for easy replacement of POOL FROG
Mineral Reservoir and POOL FROG Pac.
Minimum
12” above
opening
Minimum
12” above
opening
Minimum
12” to side
Minimum
12” to side
®
B
R
A N
D
Minerals
Chlorine
Install with water flowing
through the minerals first
and then the chlorine.
1½” Male Adapter
(slip x MPT)
or
2” Female
Adapter
(slip x FPT)
Hard-Plumbed Installation
Following Primer directions, brush Primer on the inside of the
adapters and to ends of pipe. Repeat this process with PVC
cement following manufacturer’s directions on that product.
Measure the
distance between
the outside
adapters and cut
out a section of
pipe 3” less than
that dimension.
Insert PVC pipe into adapters with
a twisting action. Hold in place 5 to
10 seconds to bond.
TOOLS NEEDED
Hacksaw
MATERIALS NEEDED
Tape
Measure
SECURE TWIN
2.
1.
3.
Pipe Wrench
Pipe Thread Tape
or Sealant, Primer and
PVC Cement
Screw adapters into each end of POOL FROG Twin Cyclers following
directions for a male adapter or a female adapter. Hand tighten.
Finish tightening by turning 1 to 2 revolutions with a pipe wrench.
DO NOT OVER TIGHTEN.
4.
5.
Primer
For better stability,
POOL FROG Twin
Cyclers may be
mounted on a treated
wood base using
Phillips pan head
screws.
One in front
and two in back of
each Cycler. If you
have questions about
stability, please contact
your dealer or King
Technology.
Primer
PVC
Cement
PVC
Cement
1a.
1b.
If using
male adapters
,
apply pipe thread tape or
sealant to the threaded end
of each adapter.
If using
female adapters
,
apply pipe thread tape or
sealant to the threaded end
of each feeder port.
Do NOT install in copper pipe if
using POOL FROG Pac as chemical
corrosion may lead to pipe failure.
The POOL FROG Twin Cyclers should always be installed
between the filter and pool (or between heater and pool if
applicable). Never install POOL FROG Twin Cyclers before
the heater or damage to the heater could occur.