Advanced parameters (service)
ID Description Limits
Scale
Factory
setting
RbP
Warning/Alarm clearing
YES = resetting only allowed locally
NO = resetting allowed locally and remotely
[3].
YES / NO
-
NO
NoA
With RbP = YES - Maximum number of local resets allowed
within the time frame defined in TtPR
1…10 1 1
TtPR
With RbP = YES - Time frame within which the maximum number of
local resets defined in NoA can be performed.
0…24
hours
[4]
1 hour
1 hour
PSPR
"Scheduled service" W6 Warning clearing
YES = Warning reset only allowed with the Service PIN
[5].
NO = Warning reset without PIN
YES / NO
-
NO
[1]
– Do not set DCC = NO with ambient temperature below 15°C. Alarms A11 and A13 could trigger with the risk of
damaging the dryer. In this case, reset the setting DCC = YES.
[2]
- With DPS = 3, the dew point varies according to the ambient temperature.
[3]
- With RbP = NO, the maximum number of remote resets allowed, within 60 minutes, is three.
[4]
- With TtPR = 0, when NoA Alarms are reached, the dryer asks for the Service PIN to be entered to reset the Alarm.
[5]
- With PSPR = YES, the SrV parameter can only be modified with the Service PIN.
10.15.17
List of spare parts
1-
With the stopped or operating dryer press
to access the dryer's menu.
2-
Press
to display the list of the dryer's spare parts.
3-
Scroll through the list of spare parts using the cursor keys
Downloading the list of spare parts:
4-
Install a USB storage drive as described in "Installing and removing the USB
storage drive" and press
to download the spare parts list. Remove the
USB drive as described in the section "Installing and removing the USB
storage drive."
5-
Press
to return to the previous screens.