4.
Insert the funnel (1) in the corresponding funnel opening on the
top of the jaw crusher.
NOTICE!
Mount the funnel as shown in the picture.
5.
Attach the funnel (1) to the housing using the previously removed
4 countersunk head screws (D).
The countersunk head screws (D) must be tightened firmly in order
that the rubber seal is compressed and tight.
4.6 Electrical connection
Before establishing the connection, compare the voltage and current
values given on the type plate with the values of the available electrical
system.
The electrical system should meet the following requirements:
n
3~ / 1~ connection
n
Fuse protection of at least 16A for the socket connection
n
or automatic circuit-breaker with 16A and "C" characteristic
n
Functioning protective earth.
4.6.1 Detection of the direction of rotation
The jaw crusher is equipped with an automatic rotation direction detec-
tion unit.
Installation