background image

112T  -  112L

Original installation instructions

IMPORTANT: 

Please read this manual carefully before using the appliance.

 

Summary of Contents for VarioCooking Center 112L

Page 1: ...112T 112L Original installation instructions IMPORTANT Please read this manual carefully before using the appliance ...

Page 2: ... 2 v03 ...

Page 3: ...ription of the appliance 10 Size of the appliance model 112T 12 Size of the appliance model 112L 14 Handling Transport and removal from pallet 16 Space requirements of the appliance 18 Installation 19 Height adjustment 22 Electrical connection 24 Water supply 27 Waste water drainage 28 First use 30 Installation options 31 Conversion table Troubleshooting 34 ...

Page 4: ... 4 v03 ...

Page 5: ...е изделия отвечают следующим нормам ЕС S FRIMA försäkrar att dessa produkter är i överensstämmelse med följande EU direktiv SER FRIMA izjavljuje da su ovi proizvodi u saglasnosti sa sledeċim smernicama EU SI FRIMA izlavlja da so ti izdelki v skladu z naslednjimi smernicami EU SK Firma FRIMA prehlasuje že výrobky sú v súlade s nasledovnými smernicami EU TR FRIMA bu ürünlerin Avrupa Birliği nin aşşa...

Page 6: ...sential infor mation Caution Indicates a potentially dangerous situation likely to lead to minor injuries Burn hazard Danger High voltage Danger of death Non observance may lead to very serious injuries or death 1 Numbering such as this 2 indicates a list of actions to be carried out step by step This symbol refers you to more detailed information The symbol corresponds to a list Warning Incorrect...

Page 7: ...nger analysis in order to inform users Caution Wear protective gloves and safety shoes during installation Fire precautions Fire hazard Do not store or use gas or flammable liquids near this appliance Use and installation Always strictly observe the instructions in this manual especially safety instructions If instructions are not observed and damages occur the manufacturer and its legal represent...

Page 8: ...er manual Glass parts bulbs joints and other components subject to wear Procedures carried out by a technician who is not trained in the equipment or appliances equipped with parts which are not the original parts Damage linked to the use of cleaning products other than those approved by the manufacturer Disposal of obsolete appliances If you wish to dispose of this appliance do not put it in the ...

Page 9: ...pply voltage Mains power Water pressure VarioCooking Center serial number For all telephone enquiries you must pro vide this number Name of the person who manufactured the appliance Each VarioCooking Center is made by one person only Certification and accreditation Country of manufacture ...

Page 10: ...t points 2 Cover 3 Hook for basket handle 4 Min Max markings for oil filling and tank measurement scale 5 Start Stop button 6 8 5 TFT Screen 7 Selection wheel 8 USB port 9 Hand spray 10 Tank emptying lever 11 Cooking tank 12 Bypass 13 Water filling duct 14 Bypass 15 Cover seal 16 Core temperature probe holder 17 Cover 18 Cover handle ...

Page 11: ...ns Energy optimisation system or Ethernet cable 20 Technical compartment A Connection of the appliance 21 Electricity supply 22 Adjustable leg s 20 60 mm 23 Technical compartment B 24 Cover to access water connection and equi potential connection 25 Waste water drainage ...

Page 12: ...liance model 112T 1 Waste water drainage DN40 2 Cold water supply G3 4 3 Electricity supply 4 Energy optimisation Option 5 Ethernet Option 6 Equipotential connection M6 x 10 7 Interchangeable foot 20 60 mm Minimum gap NB This drawing is not to scale ...

Page 13: ... 13 v03 Size of the appliance model 112T with underframe table NB This drawing is not to scale ...

Page 14: ...ce model 112L 1 Waste water drainage DN40 2 Cold water supply G3 4 3 Electricity supply 4 Energy optimisation Option 5 Ethernet Option 6 Equipotential connection M6 x 10 7 Interchangeable foot 20 60 mm Minimum gap NB This drawing is not to scale ...

Page 15: ... 15 v03 Size of the appliance model 112L with underframe table NB This drawing is not to scale ...

Page 16: ...t on pallets the appliance must always rest on its body and not on its legs Our pallets are specially equipped for this Article numbers for empty packaging Model Article Ref 112T Palet 90 00 353 Carton 90 00 352 Carton cover 90 00 380 112L Palet 90 00 474 Carton 90 00 475 Carton cover 90 00 476 Crushing hazard Be careful not to crush fingers whilst handling the appliance Be careful not to let the ...

Page 17: ...or moving it Difficult situations Fig 3 Vertical handling It is possible to temporarily handle the appliance vertically in order to pass through doorways or other confined spaces To do this the tank and cover should be strapped together Fig 3 The appliance should never be trans ported in this position for long distances for example in a car Transport and wintering Fig 4 Water present in the hydrau...

Page 18: ...weight Fig 2 VCCM 112T X Y H P kg 962 mm 37 7 8 800 mm 31 1 2 352 mm 13 3 4 99 kg VCCM 112L X Y H P kg 1102 mm 43 3 8 905 mm 35 5 8 368 mm 14 9 16 133 H Height without legs Centre of gravity Fig 2 Position of the centre of gravity of appliances Leg height Fig 3 The legs can be adjusted between 20 60 mm You should firstly choose the front central leg which best suits your equipment 20 or 60 mm See ...

Page 19: ... country Naked flames Fig 2 Right Left Back X 500 mm Crushing hazard Be careful not to crush fingers whilst handling the appliance Be careful not to let the appliance tip whilst handling it Accessing the rear compartment Fig 3 For easier access turn the appliance as shown in Fig 3 However be careful that the front leg does not fall off the work surface on which the appliance is placed Tipping haza...

Page 20: ... 20 v03 ...

Page 21: ... 4 Tip the control panel onto the left or right cover as you wish Opening the rear panels Fig 2 1 Remove the screws from the central panel 2 Remove the screws from the technical com partments 3 mm hexagonal key Removing the front leg Fig 3 1 Using a screwdriver press on the clips 2 Pull the leg The new leg can simply be clipped into place It can be inserted either way round ...

Page 22: ...iance See chapter Installation Options Our appliances are built all on the same level This means that the tank is connected to the body Adjusting the height of the tank therefore also adjusts the height of the body This adjustment can only be carried out by adjusting the back legs of the appliance This should be done as follows Crushing hazard Be careful not to crush fingers whilst handling the ap...

Page 23: ...ide where you have placed the spirit level Step 3 Fig 5 Place the spirit level on the other tank B Carry out the transverse adjustment again Step 4 Fig 6 This step should only consist of checking or minor corrections Place the spirit level on one of the tanks Now carry out the longitudinal adjustment left to right of the appliance In order to do this adjust the two back legs Check the other tank C...

Page 24: ... power is swit ched off using an external switch The switch on the appliance is not suffi cient certain parts will still be live Mains connection cable Electrical data see page 26 Connection of appliances for values and connection points see the following pages 25 26 and the technical sheets on page 12 15 Appliances may be connected permanently or using a suitable power outlet Before plugging in o...

Page 25: ...mode without heating wit hout water AlsoseechapterInstallationOptions Demonstration Mode Our appliances can be connected in demonstra tion mode single phase supply Depending on the demonstration mode chosen the heating tank filling and movements are de activated Procedure 1 Connect the appliance 2 Start the appliance and immediately activate the demonstration mode of your choice For single phase c...

Page 26: ...is strongly recommended not to use a rigid cable for connection with our appliance Maximum size of supply cables Maximum diameter Feeding through the cable glands VCCM 112T Ø Max 25 mm 1 VCCM 112L Ø Max 32 mm 1 17 64 Maximum cross section Connection to the supply terminal VCCM 112T Max 10 mm2 0 1 64 in VCCM 112L Max 16 mm2 0 5 8 in Demonstration mode power Demo mode Reduced 230 W Demo mode On full...

Page 27: ...rdness is at least 7 fH See conversion table p 34 for local values Safety Our appliance is equipped with a thermal safety mechanism In the case of overheating Pan temp 120 C 248 F the VarioDose automatic filling system cannot be used The safety mechanism is deactivated as soon as the temperature decreases General points Our appliances meet standards NF EN 1717 2001 05 and IEC 61770 approved by SVG...

Page 28: ...uld have a U bend Our appliance does not have one The drainage pipe should be the same diame ter as that of the appliance it is not accep table to insert a pipe with a smaller diameter The drainage pipe should have a constant slope of at least 3 Position VCC112T Fig 1 VCC112L Fig 2 Verifications After installation of the outlet fill the tanks with 6 litres of hot water each and carry out a test By...

Page 29: ...eg using the attachment shown in Fig 3 The clip is reversible for use on both sides of the central leg Attachment clip 60 73 406 Drainage into a drain located in front of the appliance Be aware of burn hazards It is your responsibility to protect the drainage system from detachment and to protect the end user Leave a space of at least 20 mm between the drain grate and the drainage pipe Connection ...

Page 30: ... adjust it Adjust the height in 300m steps Validate after adjustment Calibration Our VarioCooking Centers are factory calibrated It is therefore not necessary to perform a calibration after adjustment of the installation height Cleaning wipes The quality of the installation is very important to us We also deliver cleaning wipes soaked in highly refined mineral oil in the starter kit They are to be...

Page 31: ... mm legs Foam support VCCM 112T 12 01 291 Foam support VCCM 112L 60 73 713 Example of assembly Fig 2 Drainage blocking kit For clients who cannot provide a connection near to the appliance one option is to block the internal drai nage system This accessory is not factory assembled it must be assembled at the time of installation A notice is supplied with the kit Drainage blocking kit 60 73 433 Eth...

Page 32: ... 60 30 940 With casters 60 30 941 Be careful when using options such as casters They may affect the height of the appliance The underframe table is equipped with pins The legs of our appliances are perforated to allow them to interlock with these pins Mobile units Fig 4 If our appliance is mounted on a mobile unit this unit must be secured in order to avoid damage to the cables and supply pipes of...

Page 33: ... the connections indicated on the electrical diagram The supply termi nal is numbered Demonstration mode mode choice Access using buttons Or Allows you to choose any demonstration mode There are 4 possibilities Off No demonstration mode normal mode Reduced No heating no water Movements are possible On No heating no water No move ments are possible Dummy Do not use Reserved for demons tration model...

Page 34: ... mg Ca2 kg Conversion table Troubleshooting Troubleshooting Error profile Instructions Appliance will not start the screen remains black Check the safety chain F1 F2 fuses Tank overheating Klixon circuit breaker T1 F1 T1 F2 Transformer fuses F17 F22 Klixon circuit breaker No water in the hand spray Check if the water supply tap is turned on Remove the water supply pipe is the appliance s protectiv...

Page 35: ... 35 v03 ...

Page 36: ...form us Photocopy this page and write your comments indicating the exact page Send it to us by fax Our contact details can be found on the documents delivered with the appliance Comments Validity of the document Type of VarioCooking Center 112T 112L Serial number E11VI13128xxxxxx E13VJ16018xxxxxx Year of manufacture From 2013 12 2016 01 80 05 639 Page ...

Reviews: