background image

 

                                                                                                                               

 

ENG 

 

2 brakes (if they are requested) are energized, so the wheels are blocked in order to avoid any 
accident. Do not allow the access of unauthorized individuals during the cooler installation. 

c. 

The merchandiser must stand upright for at least 1 hour after transportation and prior to start-up. 
This provides sufficient time for the oil to run back to the compressor after transit and 
installation. 

d. 

Allow a minimum gap of 100mm at the back.  

e. 

Do not place anything on top of the ICM. 

 
Note: Relocation of the ICM inside the outlet 
a. 

Empty the ICM and unplug from mains supply. 

b. 

Fully extract the levelling feet. 

c. 

Move the unit to the desired location with the assistance of another person. 

 

3.2 

Connection to the mains supply 

Connect the ICM to a 220-240 Volt power supply on a min 10 A fused & grounded 
socket. Do not use extension cables. 
 

 

Do not connect the merchandiser to: 

 

a non-grounded wall socket or power line 

 

improper supply voltage and frequency 

 

power supply that does not comply with the safety regulations of 
the appliance or with current legislation on electrical installations 

 

 

 

If the mains cord supplied is not long enough, do not use an 
extension lead. Ask an authorized electrician to replace the cord 
with a longer one, only if this is described in the list of 
authorized spare parts. 

 

Do not plug the cooler into a multiple outlet strip. 

 

Route the mains cord in such a way that it is protected from 
damage and does not pose a risk of tripping. 

 

3.3 Operation 

instructions 

 

Do not use the merchandiser to store food.  
Do not store explosive substances such as aerosol cans with flammable 
propellant in this appliance. 

 

 

This appliance is not intended for use by young children or handicapped 
or infirm persons unless they are adequately supervised by a responsible 
person who will ensure the safe operation of the appliance on their part. 
Young children should be supervised to ensure that they do not play with 
the appliance. 

 

 

Do not operate the appliance while any of the cover sheets and guards is 
open. 

Summary of Contents for Flex 56 B HC

Page 1: ...ENG Flex 56 B HC Flex 65 B HC Flex 65 B ECO HC ...

Page 2: ...iginally written in English Before using this ICM please read the instructions below carefully Please see below the interpretation of the symbols used throughout the manual for your better understanding WARNING INFORMATION CAUTION FIRST AID ...

Page 3: ...nstallation operation 5 3 1 ICM placement instructions 5 3 2 Connection to the mains supply 6 3 3 Operation instructions 6 4 Care cleaning 7 5 Troubleshooting 7 6 First aid 9 7 Disposal of the unit 9 8 Recycling information 9 9 Warranty 10 APPENDIX A Handling transportation guidelines 11 APPENDIX B Preventive maintenance guidelines 11 APPENDIX C Guidelines to prevent corrosion of the cabinet 12 ...

Page 4: ...16A The outlet must be easily accessible for the purposes of installation and servicing 2 2 Climate classification According to climate specifications models Flex 56 B HC Flex 65 B HC and Flex 65 B ECO HC are Class 4 as per ISO23953 2 which means ambient temperature of 32 2 C and 65 humidity 2 3 Technical specifications Rating Voltage 220 240V 50Hz Defrosting Automatic 2 4 Physical dimensions Mode...

Page 5: ... use electrical appliances inside the food storage compartments of the appliance unless recommended by the manufacturer If the supply cord is damaged it must be replaced by the manufacturer its service provider or similarly qualified persons in order to avoid a hazard Do not place the merchandiser in direct sunlight or near heat sources radiators stoves other heating equipment outdoors without pro...

Page 6: ...ower line improper supply voltage and frequency power supply that does not comply with the safety regulations of the appliance or with current legislation on electrical installations If the mains cord supplied is not long enough do not use an extension lead Ask an authorized electrician to replace the cord with a longer one only if this is described in the list of authorized spare parts Do not plu...

Page 7: ...r to avoid mould formation odours etc product compartments must also be thoroughly cleaned The interior of the ICM should be cleaned with a mildly soapy cloth and the glass surface using a window cleaning agent In case the merchandiser is placed in very dusty and or greasy environment the regular cleaning of the condenser by an authorized technician is mandatory Keep the cooler in a stable positio...

Page 8: ...ioning properly or is out of order please check the following before calling the authorized service provider FAULT POSSIBLE REASONS HANDLING The ICM does not work Power cord not plugged in Plug it in No power supply at the socket Check the outlet fuse The cooler does not cool The ICM has recently been reloaded with warm products Please note that it takes some time to cool warm products Preferably ...

Page 9: ... minutes and then consult a doctor Contact with skin Wash immediately with water 7 Disposal of the unit For detailed information regarding the recycling of this product please contact your local city office your waste disposal service or the manufacturer through its service agent By ensuring this product is disposed of properly you will help prevent potential negative consequences for the environm...

Page 10: ... are not recycled raw materials have to be processed for the production of new products This represents significant loss of resources as the energy transport and environmental damage caused by these processes is considerable To help in the recovery and recycling process of this appliance do not dismantle or break parts off the appliance prior to collection By removing parts off the appliance you c...

Page 11: ...of an ICM once or twice a year using a vacuum cleaner Cleaning of the condenser Cleaning of the dust filters if applicable If the ICM is placed in an environment where dust is accumulated on the condenser then the condenser has to be cleaned more often Additionally it is recommended that the following operations are carried out during preventive maintenance 1 Mechanical System Check that the equip...

Page 12: ...troller and its components are functioning properly Check the cooling performance of the ICM Check the cooling circuit using the appropriate leak detector in case there is any concern or sign of refrigerant leak APPENDIX C GUIDELINES TO PREVENT CORROSION OF THE CABINET 1 Avoid damages resulting from improper installation operation improper maintenance cleaning as well as improper handling and tran...

Page 13: ...s 30 210 6165700 NORWAY FRIGOGLASS NORDIC AS Kampenes Industriomrade Bredmyra 10 12 1740 Borgenhaugen 47 69111800 POLAND FRIGOGLASS SP ZO O Lazy ul Waska 3 05 552 Wolka Kosowska 48 22 711 46 00 ROMANIA FRIGOGLASS ROMANIA SRL DN 59 Timisoara Moravita KM 16 307396 Parta Timis 40 256407530 RUSSIA FRIGOGLASS EURASIA LLC Kursovoy Pereulok 9 119034 Moscow 70 959807780 TURKEY SFA Sogutma Sanayi Ic ve Dis...

Reviews: