FAULT
POSSIBLE REASONS
HANDLING
The unit does not cool
enough or at all. The
products are warm.
The unit is loaded in such a way
that the air-circulation in the
interior is getting blocked.
Remove any products that are
placed on the suction grill next to
the front glass.
The air-circulation grille at the
lower front of the unit is blocked.
Remove any items blocking the
grille.
It is more than 6 months since the
last cleaning of the condenser.
Clean the condenser (This
operation should be performed
by a qualified technician).
The unit does not cool
enough or at all. The
products are warm.
No air is circulating in the cold
chamber.
Possible fan motor failure.
Replace motor (This type of
repair should be performed by a
qualified technician).
No air is circulating in the
condenser area at all times (note:
condenser fan operates only when
compressor runs.)
Possible fan motor failure.
Replace motor (This type of
repair should be performed by a
qualified technician).
The unit does not cool
enough or at all. The
products are warm.
Leakage on the cooling system.
Repair leakage (This type of
repair should be performed by a
qualified technician).
There is dirt blocking the inlet of
the evaporator.
Clean the evaporator(This
operation should be performed
by a qualified technician).
The unit sometimes
makes noise.
For open front units, a powerful
mechanism is needed and
consequently the unit will produce
a certain amount of noise.
Contact the service provider.
Intense metallic noise.
There is water on the
floor.
The drainage hose for condensate
water is out of the tray.
Contact the service provider.
There is a leakage in the tray.
Contact the service provider.
Excessive humid environment.
Certain days with excessive
levels of humidity, overflow of
the tray could occur.
The lights don’t work.
The light switch at the top back
side of the unit is switched off
(version without the Night Curtain).
Turn on the light switch.
The night bind is closed (versions
with a night curtain installed).
Retract the night curtain.
The lights don’t work.
The fluorescent tubes, their
starters or ballasts are out of order.
Contact the service provider.