background image

Frigidaire Side Burner 

Built-In Usage

USE AND CARE MANUAL

FOR OUTDOOR USE ONLY

MADE IN THE USA

Summary of Contents for Side Burner

Page 1: ...Frigidaire Side Burner Built In Usage USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE USA ...

Page 2: ...ers you intend on using WARNING If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flames 3 Open lid 4 If odor continues immediately call your gas supplier TESTED IN ACCORDANCE WITH ANSI Z21 58a 1998 CGA 1 6a M98 STANDARD FOR OUTDOOR COOKING GAS APPLI ANCES THIS GRILL IS FOR OUTDOOR USE ONLY Check your local building codes for the proper method of installation In the absence of...

Page 3: ...es We rec ommend keeping your gas supply lines as short as possible for best performance To ensure a per fect fit we strongly recommend that you have all components on hand prior to final construction CLEARANCE TO NON COMBUSTIBLE CONSTRUCTION For your safety a minimum of 3 clearance from the back of the grill to non combustible construction is required You should allow at least 6 side clearance to...

Page 4: ...uc tion A minimum clearance of 12 from the back of the outdoor cooking center must be maintained between the grill and any combustible construction such as wood siding of residence 3 minimum for non combustible construction The side vents on this unit can be covered for built in installations without danger of fire or without impairing the operation of the grill ...

Page 5: ...e end of the flex line to the fitting on the side of the T fitting Connect the other end of the flex line to the side burner valve See Fig 4 Note This line can be extended using a 3 8 flared coupling and an additional flex line if necessary 5 Using pipe sealant attach a 3 8 nipple to the bottom of the T fitting See Fig 5 6 Using pipe sealant attach the NG gas regulator to the 3 8 nipple See Fig 6 ...

Page 6: ... the screw holding the bezel in place on the side burner and remove bezel from front of side burner See Fig 4 5 Grasp and remove NG valve assembly from the side burner tube assembly and remove from the side burner See Fig 5 6 Install LP valve assembly into the side burner See Fig 6 Fig 1 Fig 4 Fig 3 Fig 2 Screw Bezel Flex Line Valve Assembly Underside of right side burner shelf Flex Line Fig 5 Fig...

Page 7: ...Fig 8 16 Install the new LP orifice See Fig 9 17 From the bottom of the side burner place the LP orifice into the main burner assembly fin ger tighten See Fig 10 18 Using the 7mm nut driver tighten the LP orifice in the main burner assembly See Fig 11 19 This completes the side burner conversion Fig 7 Fig 11 Fig 10 Fig 9 Fig 8 Flex line attached Top of Side Burner Looking down NG orifice LP orific...

Page 8: ...ith a wrench See Fig 14 5 Using pipe sealant attach a 3 8 flared fitting to the side and bottom of the T fitting See Fig 15 6 Attach the Flex Line to the fitting on the side of the T fitting Connect the other end of the flex line to the side burner valve See Fig 16 Note This line can be extended using a 3 8 flared coupling and an additional flex line if necessary 7 Attach the LP gas hose assembly ...

Page 9: ... needed to fit the side burner into the structure Once installed into the structure use the following steps to complete the side burner installation INSTALLATION OF SIDE BURNER PARTS 1 Install burner into side burner tray lining up the three cutouts on the underside of the burner See Fig 1 2 Install burner cap onto burner See Fig 2 3 Install grate into burner See Fig 3 Fig 1 Fig 2 Fig 3 ...

Page 10: ...old the electronic igniter button You ll hear a snapping sound It may be nec essary to hold the electronic starter button for about 4 seconds If the burner does not light in 4 seconds turn the knob to the OFF position and wait 5 min utes before trying again Repeat above steps to light remaining burners See Fig 5 Match Lighting If by chance the electronic igniter does not light the burner the burne...

Page 11: ...anties of merchantability and fitness for a particular purpose which are expressly excluded consequential or incidental damages resulting from breach of warranty which are expressly excluded 6 This limited warranty does not cover corrosion or discoloring due to lack of maintenance misuse hostile environments alterations accidents or abuse or neglect 7 This limited warranty does not cover any scrat...