background image

3

0

60 ft.

(18.28  m)

     48 ft.(14.63 m)

1

52 ft.

(15.84  m)

     40 ft.(12.19 m)

2

44 ft.

(13.41  m)

     32 ft.  (9.75 m)

3

32 ft.

  (9.75 m)

     24 ft.  (7.31 m)

4

28 ft.

  (8.53 m)

    16 ft.   (4.87 m)

0

30 ft.

 (9.14 m)

     18 ft. (5.49 m)

1

22 ft.

 (6.71 m)

     14 ft. (4.27 m)

2

14 ft.

 (4.27 m)

     10 ft. (3.05 m)

3

          NOT RECOMMENDED

VENT HOOD TYPE

(Preferred)

MAXIMUM LENGTH

of 4” (10.2 cm) Dia. Flexible Metal Duct

Number

 of

90°

 Turns

4”

(10.2 cm)

Louvered

VENT HOOD TYPE

(Preferred)

Number

 of

90°

 Turns

MAXIMUM LENGTH

of 4” (10.2 cm) Dia. Rigid Metal Duct

4”

(10.2 cm)

Louvered

(6.35 cm)

2½"

(6.35 cm)

2½"

EXHAUST SYSTEM REQUIREMENTS

Use only 4 inch (10.2 cm) diameter (minimum) rigid or
flexible 

metal 

duct and approved vent hood which has a

swing-out damper(s) that open when the dryer is in
operation. When the dryer stops, the dampers automatically
close to prevent drafts and the entrance of insects and
rodents. To avoid restricting the outlet, maintain a minimum
of 12 inches (30.5 cm) clearance between the vent hood
and the ground or any other obstruction.

 The following are specific requirements

for proper and safe operation of your dryer. Failure to
follow these instructions can create excessive drying
times and fire hazards.

 

                    Do not use plastic flexible duct to exhaust

the dryer. 

Excessive lint can build up inside exhaust system

and create a fire hazard and restrict air flow. Restricted air
flow will increase dryer times. If your present system is made
up of plastic duct or metal foil duct, 

replace it

 with a rigid or

flexible metal duct. 

Ensure the present duct is free of any

lint prior to installing dryer duct.

 

If the dryer is not exhausted outdoors,

some fine lint will be expelled into the laundry area. 

An

accumulation of lint in any area of the home can create a
health and fire hazard. 

The dryer exhaust system MUST be

exhausted to the outside of the dwelling!

 

 Do not allow combustible materials (for

example: clothing, draperies/curtains, paper) to come in
contact with exhaust system. 

The dryer 

MUST NOT

 be

exhausted into a chimney, a wall, a ceiling, or any concealed
space of a building which can accumulate lint, resulting in a
fire hazard.

 Exceeding the length of duct pipe or

number of elbows allowed in the "MAXIMUM LENGTH"
charts 

can cause an accumulation of lint in the exhaust

system.  Plugging the system could create a fire hazard, as
well as increase drying times.

 

Do not screen the exhaust ends of the

vent system, nor use any screws or rivets to assemble
the exhaust system.

 Lint can become caught in the screen,

on the screws or rivets, clogging the duct work and creating a
fire hazard as well as increasing drying times. Use an
approved vent hood to terminate the duct outdoors, and seal
all joints with duct tape. All male duct pipe fittings 

MUST

 be

installed downstream with the flow of air.

 

Explosion hazard. Do not install the dryer

where gasoline or other flammables are kept or stored.

If the dryer is installed in a garage, it must be a minimum of
18 inches (45.7 cm) above the floor. Failure to do so can
result in death, explosion, fire or burns.

In installations where the exhaust system is not described in
the charts, the following method must be used to
determine if the exhaust system is acceptable:
1.

Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.

2.

Set the dryer timer and temperature to air fluff (cool
down) and start the dryer.

3.

Read the measurement on the manometer.

4.

The system back pressure 

MUST NOT

 be higher than

0.75 inches of water column.  If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable.  If the manometer reading is
higher than 0.75 inches of water column, the system is
too restrictive and the installation is unacceptable.

INSTALL MALE FITTINGS IN CORRECT DIRECTION

C O R R E C T

I N C O R R E C T

Summary of Contents for GLEQ2152CES0

Page 1: ... commencer lire attentivement le présent document Cela simplifiera l installation et assurera la pose correcte et sécuritaire de la sécheuse Après l installation laisser ce document à proximité de la sécheuse pour référence future REMARQUE L alimentation électrique de la sécheuse doit respecter les codes et ordonnances locaux ainsi que l édition la plus récente du Code ANSI NFPA 70 ou au Canada le...

Page 2: ...ctors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS for additional instructions OUTLET RECEPTACLE NEMA 10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GAS Dryer CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximu...

Page 3: ...e dwelling Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulatio...

Page 4: ...3 1 2 13 1 2 13 1 2 13 1 2 13 1 2 34 cm 34 cm 34 cm 34 cm 34 cm 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm 2 The gas supply line should be of 1 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or ...

Page 5: ...quare centimeters 3 inches 7 6 cm from bottom and top of door NOTE Under counter and stack models 0 inches 0 cm for sides rear and top This dryer MUST be exhausted outdoors 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation CLOSET DOOR 60 sq inches 387 1 sq cm 15 38 1 cm 0 0 cm 60 sq inches 387 1 sq cm 1 2 54 cm 0 0 cm 0 0 cm 0 0...

Page 6: ...t 13 5 27 25 to front of cabinet 27 75 to clear knobs 28 5 to clear door handle 5 875 To base exhaust 5 0 4 375 To side exhausts To rear base exhausts 2 25 2 375 Gas supply pipe on rear of unit Electrical supply on rear of unit 123 19cm 72 39cm 12 7cm 11 12cm 14 93cm 69 22cm 70 49cm 72 39cm 5 72cm 6 03cm 68 58cm 34 29cm 36 91 44cm Dryer Installation Dimensions Free Standing Under Counter Stacked D...

Page 7: ... 2 and 3 for other important venting requirements 6 Installation MUST conform to current Manufactured Home Construction Safety Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes The dryer is designed under ANSI Z 21 5 1 or ANSI UL2158 CAN CSA C22 2 latest editions for HOME USE only FOAM SHIPPING PA...

Page 8: ...remove the plugs Be careful to avoid scratching the paint 5 Remove the two handle screws and remove the handle by pulling straight out from door 6 Install the plugs from Step 3 into the holes left by removing the handle screws in Step 4 7 Lay the door on a flat surface and support the edges of the door to keep it from turning Apply moderate downward pressure on the lens with both hands and rotate ...

Page 9: ...ug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician For a permanently connected dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the eq...

Page 10: ...ng the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp power cord NEMA 10 30 type SRDT through the strain relief 4 Attach the power cord neutral center wire conductor to...

Page 11: ...ructs the flow of combustion and ventilation air 5 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer to OFF and wait 5 minutes before m...

Page 12: ...îner des risques d incendie Ne pas utiliser de conduites en plastique flexiblepourévacuerl airdelasécheuse Unequantitéexcessive de charpie pourrait s accumuler dans la conduite d évacuation ce qui réduirait la circulation de l air et présenterait un risque d incendie Toute obstruction de la circulation de l air ralentit le séchage Si la conduite existante est en plastique ou en papier métallique l...

Page 13: ... cm 6 0 cm 6 0 cm 6 0 cm 6 0 cm 6 0 cm 33 3 cm 33 3 cm 33 3 cm 33 3 cm 33 3 cm 11 cm 43 8 po 9 5 cm 33 4 po 15 cm 57 8 po 9 5 cm 33 4 po 34 cm 131 2po ALIMENT ALIMENT ALIMENT ALIMENT ALIMENTA A A A ATION EN GAZ TION EN GAZ TION EN GAZ TION EN GAZ TION EN GAZ Remplacer le tuyau de raccordement en cuivre non recouvert de plastique Il FAUT utiliser du laiton inoxydable ou recouvert de plastique 1 L i...

Page 14: ...re ferme et présenter une pente de 2 54 cm 1 po au maximum INSTALLATION DANS UNE ALCÔVE OU UN PLACARD 1 Toute sécheuse installée dans une chambre à coucher une salle de bain une alcôve ou un placard DOIT être reliée à une conduite d évacuation d air se terminant à l extérieur de la maison 2 Aucun autre appareil brûlant du combustible ne doit être installé dans le même placard que la sécheuse au Ga...

Page 15: ...tion Dimensions 11 12cm 72 00 182 88cm 41 00 104 14cm 34 29cm 68 58cm 38 25 97 16cm 2 375 6 03cm Dimensions Empilées D Installation De Secheuse Dimensions D Installation De Secheuse Indépendant Et Sous Le Compteur À l espace libre ouvrez la porte Alimentation électrique sur l arrière de l unité Pipe d offre de gaz sur l arrière de l unité Ligne taille centrale pour arrière droit parti passage Aux ...

Page 16: ...sécheuse est conçue conformément à la norme ANSI Z 21 5 1 pour un USAGE DOMESTIQUE seulement 91 5 cm 91 5 cm 91 5 cm 91 5 cm 91 5 cm DÉBALLAGE DÉBALLAGE DÉBALLAGE DÉBALLAGE DÉBALLAGE 1 À l aide des quatre coins de protection de l emballage deux sur chaquecôté déposerdélicatementlasécheusesursoncôtégauche et retirer le morceau de mousse placé sous la sécheuse pour l expédition Pour ne pas endommage...

Page 17: ...que pour aider à enlever les prises Faites attention à éviter de rayer la peinture 5 Enlevez les deux vis de poignée et enlevez la poignée par la traction droite dehors de la porte 6 Installez les prises de l étape 3 sur les trous à gauche en enlevant les vis de poignée dans l étape 4 7 Étendez la porte sur une surface plate et soutenez les bords de la porte pour la garder de la rotation Appliquez...

Page 18: ...Ne pas utiliser une prise à conducteurs en aluminium avec un cordon ou une prise à conducteurs en cuivre ni l inverse Une réaction chimique se produit entre le cuivre et l aluminium qui pourrait causer un court circuit Il faut utiliser un cordon d alimentation à conducteurs en cuivre avec une prise à conducteursencuivre REMARQUE Les sécheuses qui fonctionnent avec une alimentationde208voltsaurontu...

Page 19: ...NTAGEDU DÉTENDEUR PANNEAUDEBRANCHEMENT FIL DE TERRE NEUTRE VIS DE MISE À LA TERREVERTE CORDON D ALIMENTATION TYPIQUE À 4 FILS NOIR 240 V BLANC NEUTRE ROUGE 240 V VERT FILDETERRE PRISETYPIQUEÀ4 OUVERTURES NEMA 14 30 DE 30 A DE TYPE SRDT OU ST NEMA 14 30 DE 30 A DE TYPE SRDT OU ST NEMA 14 30 DE 30 A DE TYPE SRDT OU ST NEMA 14 30 DE 30 A DE TYPE SRDT OU ST NEMA 14 30 DE 30 A DE TYPE SRDT OU ST 4 Enfi...

Page 20: ...obstruelacirculationdel air servant à la combustion et à la ventilation 6 Faire fonctionner la sécheuse sur un cycle complet pour en vérifier le fonctionnement REMARQUE Danslecasdessécheusesàgaz laconduitedoitêtre vidéedesonairavantquelebrûleurnepuisses allumer Silebrûleur ne s allume pas dans les 45 secondes qui suivent le premier démarrage l interrupteur de sûreté éteint automatiquement le brûle...

Reviews: