background image

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

(For 3 or 4 Wire, 60 Hz. Systems)

4

or 4B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions . For existing installations ONLY
- Refer to Fig. 13).

1.

Follow the manufacturer’s installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).

2.

Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).

IMPORTANT NOTE: 

 DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed.

3.

Make sure all connections are tightened securely and replace the rear
access cover (See Fig. 9).

Grounding Instructions (3-Wire Connections only):

 

A ground

strap is installed on this range which connects the center terminal of the
terminal block (Neutral) to the range chassis. The ground strap is
connected to the range by the center, lowest screw (See Fig. 13). The
ground strap must not be removed unless National, State or Local
Codes do not permit use of a ground strap.

NOTE:

  If the ground strap is removed for any reason, a separate

ground wire must be connected to the separate ground screw attached
to the range chassis and to an adequate ground source.

NOTE: 

 Non-terminated field wire compression connections must be

set at approximately 35 in./lbs.

Fig. 13

4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.

3 - Wire Permanent Connection - follow Steps 1,2 & 5 below.
4 - Wire Permanent Connection - follow Steps 1 thru 5 below.

Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):

1.

(3 & 4 - Wire Permanent Connections)

 Follow the manufacturer’s

installation instructions supplied with the strain relief and install.

2.

(3 & 4 - Wire Permanent Connections)

 Strip insulation away from the

ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground
wire on 4-Wire Connections). Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).

IMPORTANT NOTE: 

 DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed. 

NOTE: For 3-Wire Permanent

Connections skip Steps 3 & 4 and continue with Step 5.

3.

(4-Wire Permanent Connection ONLY) 

Disconnect the ground strap.

Remove the factory installed ground screw & plate to release the factory
installed copper ground strap from frame of the appliance. Cut and
discard the copper strap from the terminal block. KEEP the ground
screw, ground plate and go to Step 4.

4.

(4-Wire Permanent Connection ONLY)

 Connect the ground wire lead

(Green) to the frame of the appliance using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame
where the ground screw was originally installed.

5.

(3 & 4 - Wire Permanent Connections)

 Make sure all connections are

tightened securely and replace the rear access cover (See Fig. 9).

Fig. 14

Fig. 15

5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION.

Be sure to provide all the adequate clearances and dimensions
shown in Figs. 1, 2 & 3 before moving range into final location.

Carefully slide range into final position while inserting rear leveling leg
into and FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7).
Make sure the power cord folds into the remaining open floor area
behind the range Warmer or storage drawer. Be sure to check the
level of the range.

Summary of Contents for GLEF384G

Page 1: ...ITS SHOULD BE AVOIDED IF CABINET STORAGE IS TO BE PROVIDED THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS Español Páginas 5 8 If the information in this manual is not followed exactly a fire or electrical shock may result causing property damage personal injury or death Important Notes to the Installer Readallinstructi...

Page 2: ...ction 1 4 3 8 Socket driver or Nutdriver Additional Materials You Will Need Power Supply Cord or Copper Electrical Wiring Metal Conduit for hard wiring NORMALINSTALLATIONSTEPS 32 pilot hole 1 3 4 deep The screws provided may be used in wood or concrete material Use a 5 16 nut driver or flat head screwdriver to secure the bracket in place See Fig 6 1c Level and Position Range Level range by adjusti...

Page 3: ...move cover The terminal block will then be accessible Fig 10 4A POWER CORD CONNECTIONS Fig 11 Fig 12 4 Wire Connection Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile home requires 4 Wire connection 1 Follow the manufacturer s installation instructions supplied ...

Page 4: ...tem new branch circuit or mobile home requires 4 Wire connection 1 3 4 Wire Permanent Connections Follow the manufacturer s installation instructions supplied with the strain relief and install 2 3 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal b...

Reviews: