1
Please read ALL instructions before installing. Two people are
recommended to install this product. If a new electrical outlet
is required, have the outlet installed by a qualified electrician
before
installing unit. See#5 in Preliminary Instructions
following.
Do the following before starting to install unit. See illustrations
below.
1.
Check window opening size
- the mounting parts furnished
with this air conditioner are made to install in a wooden
sill double-hung window. The standard parts are for
window dimensions listed above. Open sash to a minimum
2.
Check condition of window
- all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
3.
Check your storm windows
- if your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG. 2, or by removing
storm window while room air conditioner is being installed.
(continued)
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
BOARD THICKNESS AS
REQUIRED, ALONG
ENTIRE STOOL. FASTEN
WITH TWO NAILS OR
SCREWS.
FIG. 1
STORM WINDOW FRAM E OR
OTHER OBSTRUCTION
P/N 220219A032
SAFETY LOCK AND
3/4'' LONG HEX HEAD
SCREW
Installation Instructions
For Heavy Duty (FAS Models) and
Median (FAM Models) Air Conditioners
Preliminary Instructions
of 19''(483mm). (FIG. 1)
Check dimensions of your unit to determine model type:
Heavy duty (FAS) Median (FAM)
Unit Height: 18 5/8”
17 5/8”
Unit Width:
26 ½”
23 ½”
Min. Window Opening: 19”
18 ½”
Min. Window Width:
31”
26 ½”
Max. Window Width:
43”
40 ½”