Front Panel 

Chassis

Accessory 

Wall Sleeve 

Accessory 

Outdoor Grille

Wall Sleeve 

Adapter

PTAC - Heat Pump and Electric Heat models_Prod Specs

Rearward Slope 

Outside Wall 

1/4

"

 Slope

Inside Wall 

Specifications  

subject to change.

Product Dimensions

Height
Width
Depth
Max. Wall Thickness

Manufacturer 

Wall Sleeve Part Number

General Electric

Amana
Trane

Friedrich

16"
42"
13-13/16"
13-13/16"

Metal Sleeve RAB71

Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep 

Wall Sleeve 
Standard-Depth Wall Sleeve 

16 X 42 X 13-3/4-in. PXWS

Wall Cutout Dimensions

Height 
Width

16-5/16"
42-3/16"

Plug Type (NEMA)

6-20P

PTAC Specifications

 Product Shipping Weight (approx.) – 126 Lbs.

 An electrical supply with grounded three-prong receptacle is required. 

The power supply circuit must be installed in accordance with current 

edition of National Electrical Code (ANSI/NFPA 70)  

and local codes & ordinances.  

 Voltage Rating – 230V / 208V / 60 Hz / 20 Amps

 Amps @ 230/208V Volts = (Cool) 2.8 / 3.0 Amps / (Backup Electric 

Heater) 13.2 / 12.2 Amps / (Heat Pump) 2.4 / 2.5 Amps

 Always consult local and national electric codes.

 Recommended Circuit Breaker – 20 Amps

 Unit equipped with 230/208V 3-wire power supply cord, NEMA plug 

type 6-20P, approximately 66" long.

 In order for condensate water to drain properly inside the unit, the 

sleeve must be installed properly: Level from right to left with a slight 

1/4" rearward pitch from the indoor side to the outdoor side as shown in 

the illustration above. Refer to the Installation Instructions on the web. 

 The drain kit listed on the Frigidaire® PTAC Accessories page can 

be used for an internal or external drain. This applies to new and 

replacement installation.

New Installation

 For new installation, Frigidaire® PTAC Sleeves are available and 

recommended for proper installation. See accessories pages for  

sleeve options.*

 Standard PTAC installation requires 13-13/16" maximum wall thickness, 

unless a wall sleeve is used.

 If the PTAC unit protrudes more than 4", then it is suggested that it be 

installed with a subbase. See accessories pages for subbase options. 

Replacement Installation

 When replacing existing PTAC with new unit, refer to Product 

Installation Guide on web to identify existing wall-sleeve manufacturer 

and size compatibility. If proper installation and slope are suspect, 

then correct installation of Frigidaire® PTAC Sleeve options 

recommended. 

 For any sleeve retrofit application, be sure that the foam seals 

(factory-installed on the tube sheets) provide a good seal between 

the grille and the outdoor coil tube sheets. These foam seals provide 

a barrier that stops air from the inside mixing with air on the outside 

(known as air recirculation).

 Using Frigidaire® wall sleeve with Non-Frigidaire grille requires 

installation of an Accessory Baffle Kit, which ensures a good seal 

between the unit and exterior grille to prevent air recirculation. Air 

recirculation is a large contributor to performance loss and premature 

damage to major components. 

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

*See Frigidaire® PTAC accessories pages attached for optional accessories. 

USA

 • 

10200 David Taylor Drive

 • 

Charlotte, NC 28262

 • 

1-866-942-1567

 • 

frigidaire.com

 

CANADA

 • 

5855 Terry Fox Way

 • 

Mississauga, ON L5V 3E4

 • 

1-866-942-1567

 • 

frigidaire.ca

FRP77PTT2R 08/11 

© 2011 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Packaged Terminal Air Conditioner (PTAC)

FRP77PTT2R    

Air Conditioner / Heat Pump / Backup Electric Heater 

Summary of Contents for FRP77PTT2R

Page 1: ...ration Simple intuitive room controls are easy for guests to operate ensuring a relaxing more comfortable stay Features like Effortless Restart and Ready Select controls reduce maintenance calls Effortless Temperature Control Frigidaire air conditioners maintain the preset room temperature so the room remains comfortable at all times and helps control energy levels SilentDesign Sound reduction pac...

Page 2: ...cluded Length of Power Cord Circuit Breaker Plug Type NEMA Features Electronic Controls Front Desk Control Ready Fan Speeds Cool Fan Heat Noise Level Indoors High Med Low Quiet Start Up Low Voltage Start Up Random Restart Protection Effortless Auto Freeze Protection Energy Save 24 Hour On Off Timer Air CFM High Med Low Air Direction Control Air Intake Filter Type Filter Access Fin Coating Slide Ou...

Page 3: ...on New Installation For new installation Frigidaire PTAC Sleeves are available and recommended for proper installation See accessories pages for sleeve options Standard PTAC installation requires 13 13 16 maximum wall thickness unless a wall sleeve is used If the PTAC unit protrudes more than 4 then it is suggested that it be installed with a subbase See accessories pages for subbase options Repla...

Page 4: ...itectural Aluminum Outdoor Grille Clear 5308815313 Architectural Aluminum Outdoor Grille Dark Brown 530448055X Architectural Aluminum Outdoor Grille Customized Color 5304480557 Stamped Aluminum Outdoor Grille Clear 5304484585 Baffle Kit Metal Wall Sleeves and Accessories The electro galvanized steel used to make this metal sleeve resists corrosion The white powder coating matches the color of the ...

Page 5: ...t and connector 5304482696 Hardwire Kit 20 Amps 5304482697 Hardwire Kit 30 Amps Decorative Subbases Supports The non electrical subbase is made of heavy gauge steel to provide support for the wall sleeve The subbase is designed to mount directly to the wall sleeve Leveling legs attach easily to the wall sleeve and offer accurate leveling and support for units 5308815315 Decorative Subbase Black 53...