background image

Summary of Contents for FRA064VU110

Page 1: ...i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i _7i _i_i_i_i_i_i_iiiiiiiii_i_i_ii_i_i_i_i_1i7_7_7_ _ _i_7i_71_7_7_i_71117_ _i _ i i i Normal Sounds i i ii Air www frigidaire com i ...

Page 2: ...o avoid cuts from sharp metal fins on front and rear coils _1 not under any circumstances cut remove _ or bypass the prong E ectricanformation The complete electrical rating of your new room air conditioner is stated on the serial plate _ _ _ Refer to the rating when checking the electrical requirements j _ Be sure the a_rcond_honer _sproperly grounded To mlnmlze shock and fire hazards I _ proper ...

Page 3: ...ATE AIR CONDITIONER Unit must be upright for one hour prior to operating Operation of Current Device Plugin press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following 1 Plug in the Air Conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST button You will notice a click as the R...

Page 4: ...NG INSERTS Normal Sounds H gt7 p tctTed Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rustling Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Vibration Unit may vibrate and...

Page 5: ...l rights reserved ii i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i i...

Page 6: ...PEED steep DO THIS PRESS TO SELECT temp timer l hi fitter med reset lo m V ON OFF A FAN SPEED steep TO USE AUTO FAN FEATURE YOU WILL SEE temp timer F auto i mad V 0N OFF A FAN SPEED fitter reset steep temp timer F auto _ hi fitter J med reset lo V ON OFF A FAN SPEED steep DO THIS PRESSFAN BUTTON CHOOSE AUTO Note Fan starts at High Speed and adjusts to a slower speeds the room temperature dictates ...

Page 7: ... A Note In this mode the fan will continue to run for 1 minu te after the compressor shuts off The fan then cycles on for 20 seconds at 10 minute intervals until the room tempe rature is above the set temperature at which time the com pressor turns back on SLEEP FEATURE ternp timer F auto _ hi i filter _ _ reed lo j reset V 0N 0FF A FAN SPEED s eep YOU WILL SEE temp timer V ON OFF A FAN SPEED F au...

Page 8: ...on the display After 5 seconds the control will automatically change the display back to the hours remaining until the unit will start stop Pressing the unit On Off button at any time will cancel the Delay Start Stop function The Delay Start Stop Feature will work until the unit either starts or stops Once that happens the above steps have to be repeated again CHECK FILTER FEATUREr YOU WILL SEE te...

Page 9: ...urned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode The control will maintain the set temperature within 2 degrees Fahrenheit between ...

Page 10: ... front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window accordingto the installation instructions Cover it with plastic or return it to the original carton D...

Page 11: ...too warm NO ice forming on cooling coil behind decorative front Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too high Set temperature to a lower setting Air directional louvers positioned improperly Position louvers for better air distribution Front of unit is blocked by drapes blinds furniture etc restricts air distribution Clear blockage ...

Page 12: ...leage expense for service calls to remote areas including the state of Alaska 12 Damages to the finish of appliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companie...

Reviews: