background image

Specifications  

subject to change.

USA

 • 

10200 David Taylor Drive

 • 

Charlotte, NC 28262

 • 

1-800-FRIGIDAIRE

 • 

frigidaire.com

 

CANADA

 • 

5855 Terry Fox Way

 • 

Mississauga, ON L5V 3E4

 • 

1-800-265-8352

 • 

frigidaire.ca

FPDF4085K 10/10 

© 2010 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Freestanding Range Specifications

 Product Shipping Weight (approx.) – 265 Lbs.

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,  

60 Hertz, fused on both sides of line with ground. 

(If local code 

permits, range may be connected by hard-wiring or by means  

of power supply cord kit.)

 Connected Load (kW Rating) @ 240 / 208 Volts = 4.5 / 3.4 kW 

 Amps @ 240 / 208 Volts = 19.0 / 16.0 Amps

 Recommended Circuit Breaker – 30 Amps

 Always consult local and national electric and gas codes.

 Make sure wall coverings around range can withstand heat generated 

by range.

 Linoleum or any other synthetic floor covering located beneath range, 

must be capable of withstanding minimum heat of 90° F above room 

temperature without shrinking, warping or discoloring. Insulating pad 

or 1/4"-thick plywood required between range and a carpeted floor.

 Do not obstruct flow of combustion air at oven vent nor around base 

or beneath lower front panel of range. Range requires fresh air for 

proper burner combustion.

 Range ships with 1/2" NPT factory regulator.

 LP Gas conversion kit supplied.

 Gas supply piping can be routed through side wall of right cabinet. 

Right side cabinet is ideal location for main shutoff valve.

 Overhead cabinetry should not exceed a 13" maximum depth.

 Absolute minimum horizontal distance between overhead cabinets 

installed to either side of appliance must be no less than maximum 

width of appliance.

 Allow 24" minimum clearance between rangetop and bottom of 

cabinet when bottom of wood or metal cabinet is protected by 

not less than 1/4" flame-retardant millboard covered with not less 

than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum 

or 0.020" copper. Allow 30" minimum clearance when cabinet is 

unprotected.

 To reduce risk of fire when using overhead cabinetry, install  

range hood that projects horizontally a recommended minimum  

of 5" beyond bottom of cabinets.

 Minimum 2-1/2" clearance required from edge of rangetop to nearest 

combustible wall on either side of range above 36" height.

 Range can be installed flush to wall with 0" minimum rear clearance.

 For installation against left side wall that extends to or beyond 

range's side panel, allow 2-3/4" minimum clearance to allow  

auxiliary oven door to open. 

 Follow all dimension requirements provided to prevent property 

damage, potential fire hazard, and incorrect countertop and  

cabinet cuts.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Freestanding Range

FPDF4085K F    

40" Dual Fuel

40" Dual-Fuel Freestanding Ranges

Professional

Summary of Contents for FPDF4085KF - 40" Dual Fuel Range

Page 1: ...ready Real Stainless Steel Real stainless steel with a protective coating that reduces fingerprints and smudges so it s easy to clean Delay Start Set your oven to begin cooking on your schedule It can be programmed from 1 to 24 hours Heavy Duty Grates and Professional Style Knobs My Favorite Setting Easily program your most used setting with the touch of a button Continuous Grates Continuous Grate...

Page 2: ...wer Drawer Control Auxiliary Oven Control Cooktop Features Right Front Burner BTU Right Rear Burner BTU Left Front Burner BTU Left Rear Burner BTU Center Extra Zone Burner BTU Oven Features Main Auxiliary Capacity Cu Ft Main Auxiliary Oven Light Rack Configuration Baking System Broiling System Main Bake Broil Elements Watts Aux Bake Broil Elements Watts Auxiliary Oven Racks Certifications Sabbath ...

Page 3: ...on kit supplied Gas supply piping can be routed through side wall of right cabinet Right side cabinet is ideal location for main shutoff valve Overhead cabinetry should not exceed a 13 maximum depth Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance Allow 24 minimum clearance between rangetop and bott...

Page 4: ...8352 frigidaire ca INSTGDLNS_SSR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front ...

Page 5: ...5 8352 frigidaire ca INSTGDLNS_TMR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...

Reviews: