background image

9

To wire through top:

Mark a line distance (A) from the right of the    

  centerline on the underside of the cabinet. Mark the 

  point on this line that is 

7

»

8

” (2.2 cm) from back wall. 

  Drill a 1

¼

” (3.2 cm) diameter hole (B) through the cab 

  net at this point. 

 

 

 

 

 

To wire through wall:

Mark a line distance (A) from the right of the  

  centerline on the underside of the wall. Mark the point  

  on this line that is 

7

»

8

” (2.2 cm) from the underside of   

  the cabinet. Drill a 1

¼

” (3.2 cm) diameter hole (B) 

  through the rear wall at this point. 

 

 

 

 

 

 

 

 

 

 

 

 

VENTING 

&KRRVHYHQWLQJH[KDXVWGLVFKDUJHIURPWKHYDULRXV

 

options listed - Style 1 - 4 that follows: 

 

Style 1 - Recirculating Hood version 

For this installation, go to “Install Range Hood  

(recirculating version)” on page 11.

2.

1.

A

Centerline

7

»

8

” (2.2 cm)

from wall,

not cabinet frame

B

A

A Centerline

7

»

8

” 

(2.2 cm)

B

6W\OH&XW2SHQLQJVIRUó´[´FP[

25.4 cm) Rectangular Vent System

Roof Venting

7RPDNHD´[ò´FP[FPUHFWDQJXODU

cutout on the underside of cabinet top and bottom:

Mark lines 

½

” (1.3 cm) and 4

¾

” (12.1 cm) from the    

  back wall on the centerline of the underside of cabinet.

Mark lines 5

¼

” (13.3 cm) to the right and left of the    

  centerline on the underside of cabinet.

Use saber or keyhole saw to cut a rectangular opening  

  for vent.

Repeat steps 1-3 for the underside of the top of the    

  cabinet.

 

 

Wall Venting

7RPDNHDò´[ò´FP[FPUHFWDQJOHLQ

the wall:

Make 2 lines by measuring 

3

»

8

” (0.9 cm) and 3

7

»

8

” 

  (9.8 cm) down from underside of cabinet and mark on 

  the centerline on the back wall.

Mark lines 5

¼

” (13.3 cm) to the right and left of the 

  centerline on the wall.

Use saber or keyhole saw to cut a rectangular opening 

  in the wall for the vent.

 

 

 

 

1.

2.

3.

4.

1.

2.

3.

Cabinet cutouts

*From wall, not cabinet frame

*

1

/

2

 (1.3 cm)

5

1

/

4

 

(13.3 cm)

5

1

/

4

 

(13.3 cm)

*4

3

/

4

 

(12.1 cm)

Cabinet  

front

Centerline

5

1

/

4

(13.3 cm)

3

7

/

8

” 

(9.8 cm)

3

/

8

 

(0.9 cm)

5

1

/

4

(13.3 cm)

Centerline

PREPARE THE LOCATION

hood 

model

Dim 

A

30” & 36” 
models

ñ»

8

” 

(21.3 cm)

hood 

model

Dim 

A

30” & 36” 
models

ñ»

8

” 

(21.3 cm)

Summary of Contents for FHWC3025MB

Page 1: ...USA 1 800 944 9044 www frigidaire com Canada 1 800 265 8352 www frigidaire ca LI30KC 316902495 May 13 ...

Page 2: ...ome common problems that might occur If you do need service help is only a phone call away Call Frigidaire Customer Services at 1 800 944 9044 Product Registration Registering your product with Frigidaire enhances our ability to serve you You can register online at www frigidaire com or by dropping your Product Registration Card in the mail Serial Plate Location Serial plate location Find it on th...

Page 3: ... the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation Work and Electrical Wi...

Page 4: ... DQG ORRVH FORWKLQJ The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all respon sibility for injury due to negligence and the warranty of WKH XQLW DXWRPDWLFDOO H SLUHV GXH WR LPSURSHU PDLQWH nance a b c d 1 2 3 4 IMPORTANT SAFETY INSTRUCTIONS WAR...

Page 5: ... M91 latest edi tion and all local codes and ordinances If codes permit and a separate ground wire is used it is UHFRPPHQGHG WKDW D TXDOL HG HOHFWULFLDQ GHWHUPLQH WKDW the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 ...

Page 6: ...the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the stan dard for Manufactured Home Installation 1982 Manu factured Home Sites Communities and Setups ANSI A225 1 NFPA 501A or latest edition or with local codes Cabinet Dimensions A 66 167 cm s...

Page 7: ...t system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than VSHFL HG 0 RI DLU PRYHPHQW 7KH VSHFL HG 0 YDULHV from locale to locale Consult your HVAC professional for VSHFL F UHTXLUHPHQWV LQ RXU DUHD Venting Methods Vent system can terminate either through the roof or wall Use 3 FP UHFWDQJXODU ...

Page 8: ...OHU VWULSV LQ locations shown Determine Wiring Hole Location Determine and clearly mark a vertical centerline on the wall and cabinet bottom 1 2 3 4 1 A A Centerline Wood filler strips recessed cabinet bottoms only Wall Cabinet bottom 3 7 6 cm 3 7 6 cm PP mounting screws VENTING REQUIREMENTS 3 FP FP 9HQW 6 VWHP Vent Piece 3 FP FP IW 90 elbow 1 5 m 3 FP FP IW flat elbow 3 7 m 3 FP FP IW wall cap 0 ...

Page 9: ... System Roof Venting 7R PDNH D ò FP FP UHFWDQJXODU cutout on the underside of cabinet top and bottom Mark lines 1 3 cm and 4 12 1 cm from the back wall on the centerline of the underside of cabinet Mark lines 5 13 3 cm to the right and left of the centerline on the underside of cabinet Use saber or keyhole saw to cut a rectangular opening for vent Repeat steps 1 3 for the underside of the top of t...

Page 10: ...OH XW 2SHQLQJV IRU ó cm Rectangular Vent Transition to Round Vent Roof Venting To make a circular vent opening on the underside of the cabinet top Mark a centerline on the underside of the top of cabinet Mark a line 5 12 7 cm from the back wall on the underside of the top of cabinet Use a compass or a circle template to draw a circle with a diameter of 7 19 cm Use saber or keyhole saw to cut the c...

Page 11: ... National Electric Code or CSA standards and local codes and ordinances There must be enough wiring from the fused disconnect RU FLUFXLW EUHDNHU ER WR PDNH WKH FRQQHFWLRQ LQ WKH KRRG HOHFWULFDO WHUPLQDO ER NOTE Do not reconnect power until the installation is complete Remove the screw from the WHUPLQDO ER FRYHU 5HPRYH WHUPLQDO ER FRYHU and set aside Remove the power supply knockout from the top or...

Page 12: ...Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock 1 Disconnect power 2 Use UL listed wire connectors and connect white wires A together 3 Use UL listed wire connectors and connect black wires B together WARNING Fire Hazard Electrically ground the blower Use copper wire Connect ground wire...

Page 13: ...OTE For installations which are venting out the roof or wall the recirculating vent cover must remain in place Do not remove as unit will not perform properly To complete the installation go to Make Electrical Connection section on page 11 3 4 5 RANGE HOOD USE The range hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking an...

Page 14: ...SODFH WKH ROG FKDUFRDO OWHU ZLWK D QHZ FKDUFRDO OWHU 4 5 1 2 3 4 5 6 A A Filter screw RANGE HOOD CARE A B A Light bulb socket B Lens cover Cleaning WARNING To Reduce The Risk Of Fire Or Electrical shock disconnect from power supply before cleaning IMPORTANT OHDQ WKH KRRG DQG JUHDVH OWHUV IUHTXHQWO according to the following instructions Replace JUHDVH OWHU EHIRUH RSHUDWLQJ KRRG IMPORTANT WHULRU 6X...

Page 15: ...t secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective bulb 1 Change the bulb 2 The light bulb is loose 2 Tighten the light bulb 3 The wires on the light switch are loose 3 Make sure the wires on light switch are connected properly The hood is not venting out properly 1 The hood might be hanging to high from the cook top 1 Adjust the distanc...

Page 16: ...ding the state of Alaska 13 14 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE REPAIR OR REPLACEMENT AS...

Page 17: ...printed in Mexico ...

Reviews: