08
Indoor unit installation
Indoor unit installation
Wall mounting brackets and dimensions
150mm/5.9in or more to ceiling
100/3.9
800/31.5
120mm/4.7in
or more to wall
Left rear side
refrigerant pipe
hole
Ф
65/2.6in
95/3.7 Indoor unit outline
120mm/4.7in
or more to wall
275/10.8
45/1.8
Right rear side
refrigerant pipe
hole
Ф
65/2.6in
Installing the Wall Mounting Bracket
Drilling the Hole
1. Install the wall mounting bracket
horizontally over the structural
parts on the wall using the spaces
indicated on the bracket, as shown
in figure 1.3.
2. In the case of tiled, concrete or
similar walls, create 13/64"
diameter holes. Place anchor
supports for the appropriate
assembly screws.
3. Install the wall mounting bracket to
1. Determine the position of the
hole for the pipes using the wall
mounting bracket and drill the
pipe hole so that it is tilted slightly
downward.
2. Always use a pipe cover with an
opening when drilling.
Wall mounting bracket
Wall
Indoor unit
Outdoor unit
0.2"-0.3"
Attention!!!
Fit the wall mounting bracket and drill holes in the wall according to the
wall structure and corresponding mounting points on the wall mounting
bracket (Dimensions are in “inches” unless otherwise stated).
the wall with 5 self-tapping screws.
4. At all times securing to the wall
studs is recommended.
Figure 1.3
Summary of Contents for FFMS091CQ10