or 4B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions . For existing installations ONLY -
Refer to Fig. 13).

1.

Follow the manufacturer’s installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).

2.

Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).

IMPORTANT NOTE: 

 DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3 nuts
are loosened or removed.

3.

Make sure all connections are tightened securely and replace the rear
access cover (See Fig. 9).

Grounding Instructions (3-Wire Connections only):

 

A ground strap is

installed on this range which connects the center terminal of the terminal
block (Neutral) to the range chassis. The ground strap is connected to the
range by the center, lowest screw (See Fig. 13). The ground strap must not
be removed unless National, State or Local Codes do not permit use of a
ground strap.

NOTE:

  If the ground strap is removed for any reason, a separate ground wire

must be connected to the separate ground screw attached to the range
chassis and to an adequate ground source.

NOTE: 

 

Non-terminated field wire compression connections must be set at

22 in./lbs. or greater. Always use 10 gauge wire or larger.

Fig. 13

4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.

3 - Wire Permanent Connection - follow Steps 1,2 & 5 below.
4 - Wire Permanent Connection - follow Steps 1 thru 5 below.

Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):

1.

(3 & 4 - Wire Permanent Connections)

 Follow the manufacturer’s

installation instructions supplied with the strain relief and install.

2.

(3 & 4 - Wire Permanent Connections)

 Strip insulation away from the

ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground
wire on 4-Wire Connections). Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).

IMPORTANT NOTE: 

 DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3 nuts
are loosened or removed. 

NOTE: For 3-Wire Permanent Connections

skip Steps 3 & 4 and continue with Step 5.

3.

(4-Wire Permanent Connection ONLY) 

Disconnect the ground strap.

Remove the factory installed ground screw & plate to release the factory
installed copper ground strap from frame of the appliance. Cut and
discard the copper strap from the terminal block. KEEP the ground screw,
ground plate and go to Step 4.

4.

(4-Wire Permanent Connection ONLY)

 Connect the ground wire lead

(Green) to the frame of the appliance using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame
where the ground screw was originally installed.

5.

(3 & 4 - Wire Permanent Connections)

 Make sure all connections are

tightened securely and replace the rear access cover (See Fig. 9).

Fig. 14

5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION.

Be sure to provide all the adequate clearances and dimensions  shown in Figs.
1, 2 & 3 before moving appliance into final location.

Carefully slide range into final position while inserting rear leveling leg into and
FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7). Make sure the power
cord folds into the remaining open floor area behind the range Warmer or storage
drawer. Be sure to check the level of the range.

Fig. 15

4

INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE

Note: Non-terminated field wire compression

connections must be set at approximately 22in./
lbs. Always use 10 ga. wire or larger.

Serial plate is located on the lower right front frame

of the appliance. Alternate location may be under

cooktop.

Serial Plate Locations:

Summary of Contents for FFEF3011LB

Page 1: ... follow These are listed in the Use Care Guide read it carefully Be sure your range is installed and grounded properly by a qualified installer or service technician Make sure the wall coverings around the range can withstand the heat generated by the range To eliminate the need to reach over the surface elements cabinet storage space above the elements should be avoided IMPORTANTSAFETYINSTRUCTION...

Page 2: ...r installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing 1a Locate the Bracket using the Template Bracket may be located on either the left or right side of the range Use t...

Page 3: ...er s installation instructions supplied with the strain relief and install Also see Figs 9 10 11 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of electrical connection may occur if these 3 nuts are l...

Page 4: ...l 2 3 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal block Follow wire locations shown in Fig 14 IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of ...

Page 5: ...iones de seguridad que usted debe seguir Tales precauciones se encuentran en la Guía de Uso y Cuidado léala atentamente Asegúrese de que la estufa esté bien instalada y sea puesta a tierra en forma debida por un instalador calificado o un técnico de servicio Asegúrese de que el revestimiento de la pared alrededor de la estufa pueda resistir el calor generado por la estufa Para eliminar la necesida...

Page 6: ...justes Deslice la estufa de nuevo a su lugar Ver Fig 7 Verifique visualmente si el tornillo nivelador trasero está insertado y firmemente asegurado por el soporte antivuelco retirando el panel inferior o la gaveta de almacenamiento Para los modelos con una gaveta calentadora o compartimiento asador sujete la estufa desde el borde superior trasero y trate de inclinarla hacia adelante cuidadosamente...

Page 7: ... 2b MODELOS QUE REQUIEREN EL JUEGO DE CABLE DE ALIMENTACION ELECTRICA PUEDE OCURRIR RIESGO DE INCENDIO O CHOQUE ELECTRICO SI SE USA UN JUEGO DE CABLE DE ESTUFA DE CALIBRE INCORRECTO SI NO SE SIGUEN LAS INSTRUCCIONES DE INSTALACION O SI NO SE USA EL SOPORTE DEL SUJETACABLES Este artefacto puede ser conectado mediante un cable de alimentación eléctrica Se debe usar solamente un juego de cable de ali...

Page 8: ...ción quede plegado en el resto del área abierta del piso detrás de la gaveta de almacenamiento o gaveta calentadora de la estufa Asegúrese de verificar la nivelación de la estufa o4B CONEXIONESDELCORDONDEALIMENTACION Instrucciones para conexión trifilar para instalaciones existentes SOLAMENTE ConsultelaFig 13 1 Siga las instrucciones de instalación del fabricante suministradas con el sujetacable e...

Reviews: