ELECTRICAL CONNECTIONS

FOR 4-WIRE SYSTEM

ELECTRIC Dryer

1. Remove the screws securing the terminal block access

cover and the strain relief mounting bracket located on
the back of the dryer upper corner.

2. Install a U.L. approved strain relief in the entry hole of

the mounting bracket. Finger tighten the nut only at this
time.

3. Remove the green neutral ground wire from the green

ground screw located above the terminal block.

4. Thread a U.L. approved 30 amp power cord, NEMA 14-30

type ST or SRDT through the strain relief.

5. Attach the green power cord ground wire to the cabinet

with the green ground screw.

6. Attach the white (neutral) power cord conductor from the

power cord and the green ground wire from the dryer
harness to the silver-colored center terminal on the
terminal block. Tighten the screw securely.

7. Attach the red and black power cord conductors to the

outer brass-colored terminals on the terminal block.

 

 Do not make a sharp bend or crimp wiring/

conductor at the connections.

8. Tighten the screws securing the cord restraint firmly

against the power cord.

9. Tighten the strain relief nut securely so the strain relief

does not turn.

10. Reinstall the terminal block access cover.

ELECTRICAL CONNECTIONS

FOR 3-WIRE SYSTEM

ELECTRIC Dryer

1. Remove the screws securing the terminal block access

cover and the strain relief mounting bracket located on
the back of the dryer upper corner.

2. Install a U.L. approved strain relief into the power cord

entry hole of the mounting bracket. Finger tighten the nut
only at this time.

3. Thread a U.L. approved 30 amp. power cord, NEMA

10-30 type SRDT, through the strain relief.

4. Attach the power cord neutral (center wire) conductor to

the silver colored center terminal on the terminal block.
Tighten the screw securely.

5. Attach the remaining two power cord outer conductors to

the outer brass colored terminals on the terminal block.
Tighten both screws securely.

 Do not make a sharp bend or crimp wiring/

conductor at connections.

6. Reattach the strain relief mounting bracket to the back of

the dryer with two screws. Tighten screws securely.

7. Tighten the screws securing the cord restraint firmly

against the power cord.

8. Tighten the strain relief nut securely so that the strain

relief does not turn.

9. Reinstall the terminal block cover.

TYPICAL 4
CONDUCTOR

RED 240V

BLACK

WHITE

GREEN GROUND

30 AMP NEMA 14-30 TYPE SRDT OR ST

TYPICAL 4
CONDUCTOR

STRAIN

RELIEF

MOUNTING

BRACKET

N U T

TIGHTEN
NUT
TO THESE
THREADS

POWER
CORD

RED

WHITE

BLACK

TERMINAL BLOCK

SILVER TERMINAL

GREEN
GROUND
SCREW

GREEN POWER CORD
GROUND WIRE

GREEN
NEUTRAL
GROUND
WIRE

POWER CORD

TIGHTEN NUT
TO THESE
THREADS

STRAIN
RELIEF
MOUNTING
BRACKET

GREEN
GROUND
SCREW

N U T

SILVER TERMINAL

GREEN
NEUTRAL
GROUND
WIRE

Summary of Contents for FEQBB30DS0

Page 1: ...al Fuel Gas Code ANSI Z223 1 NOTE The Dryer is designed under ANSI Z 21 5 1 or ANSI UL 2158 CAN CSA C22 2 latest editions for HOME USE only This Dryer is not recommended for commercial applications such as restaurants or beauty salons etc Pre Installation Requirements 2 Electrical Requirements 2 VentilationSystemRequirements 3 4 ExhaustSystemRequirements 4 GasSupplyRequirements 4 LocationofYourDry...

Page 2: ...tors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS for additional instructions OUTLET RECEPTACLE NEMA10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GAS Dryer CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximum ...

Page 3: ...nstallingdryerduct Ifthedryerisnotexhaustedoutdoors somefinelintwillbe expelledintothelaundryarea Anaccumulationoflintinany areaofthehomecancreateahealthandfirehazard Thedryer exhaustsystemMUSTbeexhaustedtotheoutsideofthe dwelling Donotallowcombustiblematerials forexample clothing draperies curtains paper tocomeincontactwithexhaust system ThedryerMUSTNOTbeexhaustedintoachimney a wall aceiling oran...

Page 4: ...bsenceoflocalcodes withtheNationalFuelGasCode ANSIZ223 1 latestedition 2 The gas supply line should be of 1 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 5 A1 8inch 0 32cm N P T pluggedtapping acc...

Page 5: ...yer 3 Yourdryerneedsthespacearounditforproperventilation DONOTinstallyourdryerinaclosetwithasoliddoor 4 Aminimumof120squareinches 774 2squarecm ofopening equally divided at the top and bottom of the door is required Airopeningsarerequiredtobeunobstructedwhenadooris installed Alouvered door with equivalent air openings for the full length of the door is acceptable Closet door ventilation required 2...

Page 6: ...t system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your de...

Page 7: ...ou may need a plastic knife to help pull out the plugs Be careful not to scratch the paint 2 Remove the four screws that secure the door hinges to the dryer front panel see below NOTE Remove one screw from each of the two hinges first Hold the door firmly before removing the last two screws 3 Rotate the door 180 and reinstall the door hinges to the dryer front panel with the four screws 4 Install ...

Page 8: ...resulting in electrical shock Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 2...

Page 9: ... screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp power cord NEMA 10 30 type SRDT through the strain relief 4 Attach the power cord neutral center wir...

Page 10: ...hing such as boxes clothing etc obstructs the flowofcombustionandventilationair 5 Run the dryer through a and cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer...

Reviews: