Frigidaire FEQBB30DS0 Installation Instructions Manual Download Page 5

5

CLOSET DOOR

60 sq. inches
(387.1 sq. cm)

15" (38.1 cm)

0" (0 cm)

60 sq. inches
(387.1 sq. cm)

1" (2.54 cm)

0" (0  cm)

0" (0 cm)

0" (0 cm)

0" (0  cm)

1" (2.54 cm)

LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather

conditions.

2. In an area where it will come in contact with curtains, drapes,

or anything that will obstruct the flow of combustion and
ventilation air.

3. On carpet. Floor MUST be solid with a maximum slope of 1

inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,

MUST be exhausted outdoors.

2. No other fuel burning appliance shall be installed in the same

closet as the Gas dryer.

3. Your dryer needs the space around it for proper ventilation.

DO NOT install your dryer in a closet with a solid door.

4. A minimum of 120 square inches (774.2 square cm) of opening,

equally divided at the top and bottom of the door, is required.
Air openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for the
full length of the door is acceptable. Closet door ventilation
required:  2 louvered openings each 60 square inches (387
square centimeters) — 3 inches (7.6 cm) from bottom and top
of door.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES     REAR

TOP

FRONT

Alcove

0 (0 cm)   0 (0 cm)

15 (38.1 cm)

Closet

0 (0 cm)   0 (0 cm)

15 (38.1 cm)

1 (2.54 cm)

NOTE:   Under counter and stack models - 0 inches (0 cm) for

sides,rear, and top.

5. The following illustrations show minimum clearance

dimensions for proper operation in a recess or closet
installation.

Summary of Contents for FEQBB30DS0

Page 1: ...al Fuel Gas Code ANSI Z223 1 NOTE The Dryer is designed under ANSI Z 21 5 1 or ANSI UL 2158 CAN CSA C22 2 latest editions for HOME USE only This Dryer is not recommended for commercial applications such as restaurants or beauty salons etc Pre Installation Requirements 2 Electrical Requirements 2 VentilationSystemRequirements 3 4 ExhaustSystemRequirements 4 GasSupplyRequirements 4 LocationofYourDry...

Page 2: ...tors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS for additional instructions OUTLET RECEPTACLE NEMA10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GAS Dryer CIRCUIT Individual 15 amp branch circuit fused with a 15 amp maximum ...

Page 3: ...nstallingdryerduct Ifthedryerisnotexhaustedoutdoors somefinelintwillbe expelledintothelaundryarea Anaccumulationoflintinany areaofthehomecancreateahealthandfirehazard Thedryer exhaustsystemMUSTbeexhaustedtotheoutsideofthe dwelling Donotallowcombustiblematerials forexample clothing draperies curtains paper tocomeincontactwithexhaust system ThedryerMUSTNOTbeexhaustedintoachimney a wall aceiling oran...

Page 4: ...bsenceoflocalcodes withtheNationalFuelGasCode ANSIZ223 1 latestedition 2 The gas supply line should be of 1 2 inch 1 27 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 5 A1 8inch 0 32cm N P T pluggedtapping acc...

Page 5: ...yer 3 Yourdryerneedsthespacearounditforproperventilation DONOTinstallyourdryerinaclosetwithasoliddoor 4 Aminimumof120squareinches 774 2squarecm ofopening equally divided at the top and bottom of the door is required Airopeningsarerequiredtobeunobstructedwhenadooris installed Alouvered door with equivalent air openings for the full length of the door is acceptable Closet door ventilation required 2...

Page 6: ...t system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 346764 is available from your de...

Page 7: ...ou may need a plastic knife to help pull out the plugs Be careful not to scratch the paint 2 Remove the four screws that secure the door hinges to the dryer front panel see below NOTE Remove one screw from each of the two hinges first Hold the door firmly before removing the last two screws 3 Rotate the door 180 and reinstall the door hinges to the dryer front panel with the four screws 4 Install ...

Page 8: ...resulting in electrical shock Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 2...

Page 9: ... screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp power cord NEMA 10 30 type SRDT through the strain relief 4 Attach the power cord neutral center wir...

Page 10: ...hing such as boxes clothing etc obstructs the flowofcombustionandventilationair 5 Run the dryer through a and cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the timer...

Reviews: