background image

4

   

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Grounding type wall
receptacle

Do not, under any
circumstances, cut,
remove, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Read all instructions before using this air conditioner.

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen. This information

can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.

• If the air conditioner is to be installed in a window, you will probably want to clean both

sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation.

• Be sure the air conditioner has been securely and correctly installed according to the

separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.

• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front

and rear coils.

• Do not cover appliance with clothes of any other objects.

Electrical Information

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,

proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall

receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.

• Do not run air conditioner with outside protective cover in place. This could result in

mechanical damage within the air conditioner.

Do not use an extension cord or an adapter plug.

Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs,
enclosures, or other buildings.

• The capacity of the room air conditioner must fit the room size for efficient and satisfactory

operation.

• Install the room air conditioner on the shady side of your home. A window that faces north

is best because it is shaded most of the day.

• Close the fireplace damper, floor and wall registers so cool air does not escape up the

chimney and into the duct work.

• Keep blinds and drapes in other windows closed during the sunniest part of the day.
• Clean the air filter as recommended in the section “Care and Cleaning.”
• Proper insulation and water stripping in your home will help keep warm air out and cool air

in.

• External house shading with trees, plants or awnings will help reduce the air conditioner’s

work load.

• Operate heat producing appliances such as ranges, washers, dryers and dishwashers

during the coolest part of the day.

Energy Saving Ideas

Important Safety
Instructions

The power supply cord with

this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired it must be
replaced with a cord from the Product
Manufacturer.

SZ000373(En)-YaoKong(p1-5)

2004.11.10, 4:54 PM

4

Summary of Contents for FAP094P1Z - 9,000-BTU Portable Air Conditioner

Page 1: ...TIONER ELECTRONIC CONTROL THIS PORTABLE AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS P N 220250d396 SZ000373 En YaoKong p1 5 2004 11 10 4 54 PM 1 ...

Page 2: ...ment of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does n...

Page 3: ...r Your Product The self addressed PRODUCT REGISTRATION CARD should be filled in completely signed and returned to the Frigidaire Company 2 Warranty 3 Product Registration 3 Normal Sounds 4 Important Safety Instructions 4 Energy Saving Ideas 5 Operation of Current Device Description Accessories 6 10 Air Conditioner Features 10 Care and Cleaning 11 Avoid Service Checklist Product Registration Conten...

Page 4: ...properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electric...

Page 5: ...n for correct operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer Unit Description Accessories Included Check all the accessories are included in ...

Page 6: ...R INDICATOR ON OFF BUTTON TIMER BUTTONS REMOTE SIGNAL RECEIVER TEMPERATURE CHANGE BUTTONS TEMP TIMER DISPLAY FAHRENHEIT CELSIUS INDICATORS Fig 3 REMOTE CONTROL MODE INDICATION MODE SELECTOR FAN SPEED SELECTOR FAN SELECTION TEMPERATURE CONTROL BUTTONS TIMER BUTTONS ON OFF BUTTON RESET LOCK PIN BUTTONS SZ000373 En YaoKong p6 11 2004 11 8 4 02 PM 6 ...

Page 7: ...tinuous drainage Refer to the drainage section Fig 7c Fig 8 Exhaust Air Oulet Exhaust Adaptor Fig 5 Fig 6 Fig 7a Fig 7b EXHAUSTING HOT AIR In the COOLING Mode the appliance must be placed close to a window or opening so that the warm exhaust air can be ducted outside First position unit on a flat floor and make sure there s a minimum of 12 clearance around the unit and is within the vicinity of a ...

Page 8: ...p doors windows closed for best effect FAN MODE TEMPERATURE DISPLAY The display can be changed to read either Fahrenheit o F or Celsius o C To do this simply hold the Temp buttons for three seconds Note the remote can only display the temperature in Fahrenheit o F To start unit at a pre determined time Make sure that the appliance is in the same mode you will need when it turns back on Then turn t...

Page 9: ...ide and then remove the continuous drain stopper to let the internal bucket drain If hose drainage is being used and no blockages or kinks can be found then wheel the unit to a drainage point outside and drain as described above Fig 12 Replace the stopper when drained The remote control operates the unit in the same way as the control panel buttons with the exceptions noted below AUTO FUNCTION The...

Page 10: ...ce a month to see if cleaning is neces sary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Pull open the filter cover by grasping the handle at the bottom Remove the filter Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thor oughly dry before ...

Page 11: ...ehind air filter Straighten away from coil Reset to a Lower temperature Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Outdoor temperature below 60 F 18 C To defrost the coil set FAN ONLY Mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY Mode Temperature is set t...

Reviews: