Summary of Contents for CARE1011MW0

Page 1: ...TABLE OF CONTENTS Installation Requirements _10 NoteS_ _ iiiiiiiiiiiiii iiii iiii i ii iiiiii iiiiii 20 Installation Instructions 11 16 r _n_i_ Reversing Door 7 18 O ...

Page 2: ...t editions for HOME USE only This dryer is not recommended for commercial applications such as restaurants beauty salons etc Do not install a clothes dryer with flexible plastic or flexible foil venting material Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire The instructions in this...

Page 3: ...ting Free flowing clear of lint buildup 4 inch 102 mm rigid or semi rigid ducting of minimal length and turns NO foil or plastic venting material Approved vent hood exhausted to outdoors Leveling Dryer is level side to side and front to back Cabinet is setting solid on all corners Gas Supply Gas Dryer Manual shutoff valve present in supply All connections sealed with approved sealer and wrench tig...

Page 4: ...permit grounding OUTLET RECEPTACLE NEMA 10 30R or NEMA 14 30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position GROUNDING CONNECTION See Grounding requirements in Electrical Installation section 3 WIRE POWER SUPPLYCORD KIT not supplied 3 wire receptacle NEMA type 10 30R The dryer MUST employ a 3 conductor power supply cord NEMA 10 30 type S...

Page 5: ...codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve installed in accordance with the B149 1 Natural Gas and Propane Installation Code B A 1 8 inch 0 32 cm N RT plugged tapping accessible for test gauge connection MUST be instal...

Page 6: ...D Failure to follow these instructions can create excessive drying times and fire hazards The following are specific requirements for proper and safe operation of your dryer FIRE HAZARD Do not install a clothes dryer with flexible plastic or metal foil venting materials Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer air...

Page 7: ...e hazard Do not screen the exhaust ends of the vent system or use any screws rivets or other fasteners that extend into the duct to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and ii creating a fire hazard as well as increasing drying ii times Use an approved vent hood to terminate the duct outdoors and seal all joints with metal ...

Page 8: ...ystem is acceptable certain extenuating circumstances could affect the performance of the dryer o Only rigid metal duct work should be used Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint Compression or crimping of the ...

Page 9: ...ling a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 6 Installer MUST anchor this 1 dryer or 2 dryer mounted on pedestal to the floor with approved Mobile Home Installation Kit P N 137067200 Installation in a Recess or Closet 1 A dryer installed in a bedroom bathroom recess or closet MU...

Page 10: ... it must be a minimum of 18 inches 45 7 cm above the floor Failure to do so can result in death exp os on fire or burns MINIMUM INSTALLATION CLEARANCES Inches cm SIDES REAR TOP FRONT Alcove 0 0 cm 0 0 cm 23 58 5 cm n a Closet 0 0 cm 0 0 cm 23 58 5 cm 1 2 5 cm Dryer must be vented straight back to achieve 0 0 cm rear installation 0 0 0 cm 0 cm 1 0 2 5 cm 0 cm _ _ _ _ _ f l Dryer Dimensions I_ 27 68...

Page 11: ... The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle Dryers operating on 208 volt power supply will have longer drying times than dryers operating on 240 volt Grounding requirements Electric dryer USA ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if...

Page 12: ... accordance with all local codes and ordinances If in doubt call a licensed electrician 3 DO NOT modify the plug provided with this appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician Grounding requirements Gas dryer USA and Canada I The dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged d...

Page 13: ...r the connection Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections Shutoff Valve Open position Manual GAS FLOW Shutoff Flare _ Flare Valve Union Union l sed _ _ Nipple Flexible Inlet Pipe on Open Connector Back of Dryer All connections must be wrench tightened 4 Check for gas system leaks with a manometer If a manometer is not avai...

Page 14: ...re conductor to the SILVER colored center terminal on the terminal block Tighten the screw securely 6 Attach the remaining two power cord outer conductors to the outer BRASS colored terminals on the terminal block Tighten both screws securely ELECTR ICAL SHOCK HAZARD Do not make a sharp bend or crimp wiring conductor at connections 7 Follow manufacturer s guidelines for firmly securing the strain ...

Page 15: ...rew Tighten the screw securely 7 Move the internal dryer harness ground WHITE wire to the terminal block and attach it along with the neutral WHITE power cord wire conductor to the center SILVER colored terminal on the terminal block Tighten the screw securely 8 Attach the RED and BLACK power cord conductors to the outer BRASS colored terminals on the terminal block Tighten both screws securely EL...

Page 16: ...r to comer 4 Press down on alternate corners and sides and feel for the slightest movement Adjust the appropriate leg s so the dryer sits solidly on the floor on ALL four legs Keep the leveling leg extension at a minimum for best performance of the dryer Be sure the power is off at a circuit breaker fuse box before PlUgging the power cord into an outlet 5 Plug the power cord into a grounded outlet...

Page 17: ...ss otherwise noted Figure below Place door on a towel front side down to prevent scratches to paint or window if equipped Remove all four remaining long hinge screws on edge of door Figure below Youmayneeda plasticknifeto helppullout the plugs Be careful not to scratch the paint ii o D STAMPED ON DOOR SIDE OF HINGE INTERIOR Begin removing the four short screws that attach the hinge to the front pa...

Page 18: ...e hole to the top hole in the front panel door opening Once the first short screw is started attach the second short screw to the lower hinge Once both screws are tightened install the remaining two short screws Figure below D STAMPED ON DOOR SIDE OF HINGE INTERIOR 6 Install four long screws into holes that had secured the hinges Figure above 7 Remove striker and discard Figure below 8 Remove squa...

Page 19: ...Other colors may be available Contact the source where you purchased your dryer Technical Sheet Wiring Diagram A wiring diagram and technical data sheet are located To remove the console faceplate follow the directions below 1 Disconnect dryer from electrical source 2 Remove the hole plugs on the back of the console housing 3 Insert a small straight blade screw drive to gently pry downward on each...

Page 20: ......

Page 21: ...TABLE DESMA_RES Mesures de s_curit_ importantes 22 23 In_Fsion de la po_e 37 38 Instructions d instaIlation 31 36 ...

Page 22: ...ecommand6 d utiliser cette s6cheuse pour des usages commerciaux comme des restaurants des salons de coiffure etc N installez pas une s6cheuse avec du mat6riel d _vacuation en plastique ou en feuille m6tallique flexible Le mat6 riel de ventilation flexible peut s _craser facilement et emprisonner la charpie Ces conditions nuiraient _ 1 6coule ment d air de votre s6cheuse et pourraient accroTtre le ...

Page 23: ...ible II n y a AUCUN materiel de ventilation en papier d aluminium ou en plastique 1 1Le syst_me d _chappement dolt _vacuer I air a I ext_rieur a I aide d un _vent approuve Mise _ niveau 1 1La s_cheuse est au niveau lat_ralement et de I avant vers I arri_re Les quatre coins de la caisse reposent fermement sur le plancher Alimentation au gaz s_cheuse au gaz l l Le conduit d alimentation comporte un ...

Page 24: ..._cheuse est _ sa position de fonctionnement CONNEXION DE MISE _ LA TERRE Consultez la rubrique Exigences de mise _ la terre dans la section d installation _lectrique TROUSSE DE CORDON D ALIMENTATION A TROIS FILS non fournie TROUSSE DE CORDON D ALIMENTATION _ QUATRE FILS non fournie Prise _ 3 alv_oles NEMA type 10 30R Prise _ 4 alv_oles NEMA type 14 30R La s_cheuse DOIT utiliser un cordon d aliment...

Page 25: ...ible ANSI Z223 1 derni_re version s il n existe pas de codes Iocaux 2 Le tuyau d alimentation en gaz dolt _tre d un diam_tre int_rieur de 1 27 cm 1 2 po 3 Si les codes le permettent un tuyau m_tallique flexible peut _tre utilis_ pour raccorder votre s_cheuse au tuyau d alimentation en gaz Le tuyau DOIT _tre fabriqu_ en acier inoxydable ou en laiton avec rev_tement en plastique 4 Le tuyau d aliment...

Page 26: ...s pourrait augmenter d_mesur_ment les temps de s_chage et entra ner des Vous trouverez ci dessous les exigences pour I utio lisation adequate et s_curitaire de votre appareil RISQUE B NcENBiE N installez pas une s_cheuse avec du materiel d _vacuation en plastique ou en feuille m_tallique flexible Le materiel de ventilation flexible peut s _craser facilement et emprisonner la charpie Ces conditions...

Page 27: ...qu ils se prolongent dans la ii conduite du syst_me d _vacuation De la charpie pourrait s accumuler sur le grillage les vis ou les rivets et obstruer I _coulement d air dans le syst_me entraTnant un risque d incendie et ii I augmentation des temps de s_chage Utilisez une bouche d _vacuation approuv_e pour terminer la conduite _ I ext ieur et scellez tousles joints avec du ruban m_tallique Toutes l...

Page 28: ...influer sur le rendement de I appareil o Seule une conduite m6tallique rigide dolt 6tre utilis_e L 6vacuation verticale par le toit peut entra_ner le ph6nom6ne de contre tirage ce qui accroTt la restriction du syst6me d 6vacuation L acheminement de la conduite d 6vacuation dans un endroit non isol6 peut entra_ner de la condensation et I accumulation plus rapide de charpie Le fair de comprimer ou d...

Page 29: ...ions doivent 6tre prises pour permettre I entr6e d air d appoint de I ext6rieur Cette installation ne doit pas mesurer moins de deux fob la surface de la bouche d 6vacuation 6 L installateur DOIT ancrer 1 cette s6cheuse ou 2 la monter sur un socle au sol avec une trousse d installation de maison mobile n de piece 137067200 Installation darts un Endroit en Retrait ou une Armoire 1 Une s6cheuse inst...

Page 30: ...ol Le non respect de cette recommandation peut entra_ner un choc 61ectrique une expIoS n U nce nd e o m_me Ia mort DI_GAGEMENTS MINIMAUX Centim_tres pouces COT _S ARRII_RE DESSUS AVANT AIc6ve 0 cm 0 po 0 cm 0 po 58 5 cm 23 po n a Placard 0cm 0po 0cm 0po 58 5cm 23po 2 5cm lpo Une installation _ sortie directe permet d avoir un d_gagement de 0 cm 0 po 0 cm 0 cm 0 po 0 po _ _ _ _ 2 5 cm 0 cm 1 po O p...

Page 31: ...rait entraTner un court circuit II faut utiliser un cordon une fiche et une prise avec des ills en cuivre Les s6cheuses aliment6es par une tension de 208 V poss_deront des temps de s6chage plus longs qu une s_cheuse aliment_e par une tension de 240 V Exigences de raise _ la terre S_cheuse _iectrique I_ U RISQUE DE CHOC I LECTRIQUE Un raccordement inad6quat du conducteur de mise _ la terre de 1 6qu...

Page 32: ...tricien qualifi 3 NE MODIFIEZ PAS la fiche fournie avec cet appareil Si elle ne s ins_re pas dans la prise demandez _ un _lectricien qualifi_ d installer la prise adapt_e Exigences de raise _ la terre S_cheuse _ gaz E U et Canada 1 Cet appareil est muni d une fiche _ trois broches mise _ la terre pour assurer votre protection contre les chocs _lectriques Cette fiche doit _tre branch_e directement ...

Page 33: ... Raccord d arr_t union _ union manuel _vasement _vasement _ _ Duse Raccord Tuyau d entr_e Ouvert flexible raccord6 _ I arri6re de la s6cheuse Tousles raccords doivent tre serr_s au moyen d une cl_ Ouvrez le robinet d arr_t dans la conduite d alimentation de gaz pour permettre au gaz de s _couler dans le tuyau Attendez quelques minutes pour que le gaz s _coule dans la conduite 4 Robinet d arr6t en ...

Page 34: ...ez les deux autres fils aux bornes externes en LAITON du bornier Serrez bien les deux vis _ j _ Vis du panneau _ 2 _ _ d acc_s r Bloc de y_ S_ _ _J f_r anc heme nt Fil 2 _L ___f Borne en _ LAITON i_F Fil neutre _1 _ i__ Borne en ARGENT B rne _ 1ALTON Mise A la terre interne Vis VERTE __ J Installez un r_ducteur de tension certifi_ UL ici Fente de r_cup_ration pour les vis des bornes RISQUE DE CHOC...

Page 35: ... terre VERTE Serrez bien la vis 7 D6placez le fil de mise _ la terre du faisceau 61ectrique interne BLANC au bornier et fixez le avec le fil neutre du cordon d alimentation BLANC _ la borne centrale ARGENT du bornier Serrez bien la vis 8 Fixez les ills ROUGEet NOIR du cordon d alimentation aux bornes externes en LAITON du bornier Serrez bien les deux vis RISQUE DE CHOC ELECTRIQUE N effectuezpas de...

Page 36: ...itent un r_glage Ajustez les pieds de mise _ niveau appropri_s de mani_re _ ce que la laveuse repose solidement sur ses QUATRE pieds Gardez les pieds de mise _ niveau le plus pros possible de la laveuse afin d optimiser le rendement de la s_cheuse Assurez vous que I alimentation _lectrique est couple au disjoncteur ou au bo_tier de fusibles avant de brancher le cordon d alimentation dans une prise...

Page 37: ...cez la porte sur une serviette c6t_ avant contre le sol pour 6viter d _gratigner la peinture ou la fen_tre le cas _ch_ant Enlevez les quatre grandes vis qui retiennent les charni_res _ la porte Voir I illustration cFdessous Un couteau _ mastic en plastique peut s av6rer n6cessaire pour retirer les bouchons Prendre soin de ne pas 6gratigner la peinture ii La lettre D est grav6e _ I int6rieur des ch...

Page 38: ...e vis engag_e fixez la deuxi_me vis dans la charni_re inf_rieure Apr_s avoir serr_ les deux vis fixez et serrez les deux derni_res petites vis voir I illustration ci dessous LA LETTRE D DOIT APPARAITRE L INTERIEUR DE LA CHARNIERE C TEPORTE 6 Installez quatre grandes vis dans les trous qui servaient fixer les charni_res voir I illustration cFdessus 7 Enlevez la g_che et jetez la Volt I illustration...

Page 39: ...la console de I appareil Pour enlever la plaque avant de la console suivez les instructions ci dessous 1 D_branchez la s_cheuse de sa source d alimentation en _lectricit 2 Enlevez les bouchons situ6s _ I arri_re du bottler de la console 3 Ins_rez la lame d un petit tournevis _ lame plate pour abaisser I_g_rement chacune de pattes de fixation de la plaque avant 4 D_posez doucement la plaque de la c...