PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:

1. Phillips screwdriver
2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter’s level.

ELECTRICAL REQUIREMENTS

CIRCUIT

 - Individual, properly polarized and grounded

15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.

POWER SUPPLY

 - 2 wire, with ground, 120 volt, single

phase, 60 Hz, Alternating Current.  

NOTE:

 Because of

potential inconsistent voltage capabilities, the use of this
washer with power created by gas powered generators,
solar powered generators, wind powered generators or
any other generator other than the local utility company
is not recommended.

OUTLET RECEPTACLE

 - Properly grounded 3-prong

receptacle to be located so the power supply cord is

accessible when the washer is in an installed position.

NOTE: 

GFI (Ground Fault Interrupter) receptacle is not

required.

GROUNDING REQUIREMENTS

Improper connection of the equipment

grounding conductor can result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt as to whether the appliance is properly grounded.

1.

The washer 

MUST

 be grounded. In the event of

malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.

2.

Since your washer is equipped with a power supply
cord having an equipment-grounding conductor
and a grounding plug, the plug 

MUST

 be plugged

into an appropriate, copper wired receptacle that
is properly installed and grounded in accordance
with all local codes and ordinances or in the

24 in.

(61 cm)

Min.

96 in.

(244 cm)

Max.

BACK

absence of local codes, with the National Electrical
Codes, ANSI/NFPA 70 (latest edition). If in doubt,
call a licensed electrician. 

DO NOT

 cut off or alter

the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present,
it is the owner’s responsibility to have a licensed
electrician replace it with a 

properly grounded

three prong grounding type receptacle.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets 

MUST

 be installed within

42 inches (107 cm) of your washer’s water inlet. The
faucets 

MUST

 be 3/4 inch (1.9 cm) garden hose type

so inlet hoses can be connected. Water pressure 

MUST

be between 30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.) Your water
department can advise you of your water pressure. The hot
water temperature should be about 140 degrees F (60 degrees
C).

DRAIN REQUIREMENTS

1.

Drain capable of eliminating 17 gals (64.3 L) per
minute.

2.

A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.

3.

The standpipe height above the floor should be:

Minimum height:

24 in. (61 cm)

Maximum height:

96 in. (244 cm)

NOTE:

Drain hose attached to the washer can reach a 90
in. (229 cm) high standpipe. For higher standpipe,
use hose P/N 

134369410

, available from an

authorized parts distributor.

Summary of Contents for BLTF2940ES3

Page 1: ...ion Of Your Washer 4 Unpacking 4 Installation 5 6 Replacement Parts 6 Printed in U S A P N 134678000 0512 For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF...

Page 2: ...er supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the 24 in 61 cm Min 96 in 244 cm Max BACK absence of local codes with the National Electrical Codes ANSI NFPA 70 latest edition If in doubt call a licensed ele...

Page 3: ... the pedestal For stacking installations see additional installtion instructions included with the stacking kit For under counter installations no special top is required ROUGH IN DIMENSIONS inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm ...

Page 4: ...ont 1 in 2 54 cm Closet door ventilation required 2 louvered openings each 60 in2 387 cm2 3 in 7 6 cm from top and bottom of door UNPACKING 1 Cut the shipping carton along the dotted line along the bottom Remove the carton 2 Using a rug blanket or piece of cardboard to protect the floor lay the washer on it s back 3 Remove and save the styrofoam base and shipping plug POWER CORD Remove 4 shipping ...

Page 5: ...t might clog up the water valve screens 2 Remove the inlet hoses and rubber washers from the plastic bag located in the drum of the washer and install the rubber washers in each end of the inlet hoses 3 Carefully connect the inlet hose marked HOT to the outside H outlet of the water valve Tighten by hand then tighten another 2 3 turn with pliers Carefully connect the other inlet hose to the inside...

Page 6: ... washer Pedestal A pedestal accessory Model No NLPWD15 specifically designed for this washer may be used when elevating the washer for ease of use Failure to use accessories certified by the manufacturer could result in personal injury property damage or damage to the washer REPLACEMENT PARTS If replacements parts are needed for your washer contact the source where you purchased your washer call 1...

Page 7: ...change 6 Imprimé aux Etats Unis N P 134678000 0512 Pour votre sécurité suivre les directives données dans le présent guide afin de minimiser les risques d incendie d explosion de dommages matériels de blessures et de mort Ne pas entreposer ni utiliser d essence ou d autres vapeurs ou liquides inflammables à proximité de cette sécheuse ou de tout autre appareil électroménager QUE FAIRE S IL Y A UNE...

Page 8: ...e téléphone d un voisin Suivre les instructions de la compagnie de gaz S il est impossible de joindre la compagnie de gaz appeler les pompiers L installation et les réparations doivent être effectuées par un technicien qualifié un agent de service ou la compagnie de gaz Imprimé aux États Unis 24 in 61 cm Min 96 in 244 cm Max BACK ARRIÈRE 1 La laveuse DOIT être mise à la terre En cas de mauvais fon...

Page 9: ... d alimentation Boyau d évacuation NOTE Pour les installations de piédestal Voir les instructions d installation supplémentaires incluses avec le piédestal NOTE Pour les installations de superposition Voir les instructions d installation supplémentaires incluses avec le kit de superposition NOTE Pour les Pour des installations d undercounter aucun dessus spécial n est exigé ...

Page 10: ...2 54 cm 1 po Ventilationrequisedanslaporteduplacard 2ouvertureschacune 2 volets de 387 cm2 60 po2 chacun à 7 6 cm 3 po du bas et du haut de la porte DÉBALLAGE 1 Couper le carton d emballage le long de la ligne pointillée dans le bas Retirer la carton 2 Coucher la laveuse sur son panneau arrière Employez une tapis unecouvertureouunmorceaudecartonpourprotéger le plancher 3 Retirer la base en styrofo...

Page 11: ...qu il n y a pas de fuite REMARQUE Utilisez seulement les nouveaux boyaux fournis aveccet appareil Mise à niveau de la laveuse Le bruit et la vibration excessifs peuvent être empêchés en nivelant correctement la laveuse 1 Pour l installation debout libre et avec la laveuse en elle est la position finale placent un niveau sur la laveuse Ajustez les jambes de mise à niveau ainsi la laveuse est et coi...

Page 12: ... le serre câble fourni dans le paquet de clôture à la colonne le tuyau d admission le baquet de blanchisserie etc ainsi le tuyau ne retire pas de la force de l eau 6 Brancher le cordon d alimentation électrique dans une prise murale mise à la terre REMARQUE S assurer que le courant est coupé à la boîte de fusibles ou de disjoncteurs avant de brancher le cordon dans la prise 7 Remettre le courant à...