Air Conditioner Features

(continued)

TO USE AUTO COOL FEATURE:

YOU WILL SEE:

   DO THIS:

PRESS AUTO
      COOL

TO OPERATE ON FAN ONLY:

YOU WILL SEE:

  DO THIS:
    

PRESS 

    MODE 
  BUTTON,
  CHOOSE 
      FAN  

NOTE: 

Use this function only when cooling is not desired, such 

as for room air circulation or to exhaust stale air. (Remember to
open vent during this function, but keep it closed during cooling
for maximum cooling efficiency.) You can choose any fan speed

TO USE THE ENERGY SAVER FEATURE:

YOU WILL SEE:

               DO THIS:
   

PRESS  MODE BUTTON 

 CHOOSE ENERGY SAVER

NOTE

: In  this  mode,  the  fan  will  continue to run for 3 minutes 

after the compressor shuts off. The fan then cycles on for 2 
minutes at 10 minute intervals until the room temperature is 
above the set temperature, at  which time the compressor 

NOTE: 

Fan starts at High Speed and adjusts to a slower speed

as the room temperature dictates. For example if the room does
not get too warm, it will stay at the slowest speed. If the room 
temperature rises quickly, such as a door being opened, it will
automatically go to the highest speed. The fan speeds will 
re-adjust back to the slowest speed as the room returns to the 
original set temperature. Press either the fan slower or fan 

LIGHT 
ON

LIGHT ON

LIGHT ON

7

 
faster button to adjust the fan speed manually.

you prefer.
During  this  function,  the  display  will  show  the  actual   room 
temperature, not the set  temperature as in the cooling mode.

turns back on and cooling starts.

Summary of Contents for 819042150-01

Page 1: ...UAL THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CONTROLS P N 819042150 01 ...

Page 2: ...consequential damages so this limitation or exclusion may not apply to you 2 Service calls which do not involve malfunction or defects in workmanship or material or for appliances not in ordinary household use The consumer shall pay for such service calls 3 Damages caused by services performed by persons other than authorized Frigidaire servicers use of parts other than Frigidaire Genuine Renewal ...

Page 3: ...t passing through the evaporator during normal operation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Pinging or Swishing Droplets of water hitting the condenser during normal operation may cause pinging or swishing sounds V...

Page 4: ...d To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug and a current leakage detection device for protection against shock firehazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breake...

Page 5: ...rect operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yoursel...

Page 6: ...O CHANGE TEMPERATURE SETTING YOU WILL SEE DO THIS PRESS TO RAISE PRESS TO LOWER NOTE Tap or hold either up or down button until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 60 F 15 and 90 F 32 If you want the display to read the actual room temperature See To Operate on Fan Only section on Page 7 TO ADJUST FAN SPEEDS YOU WILL SEE...

Page 7: ...g efficiency You can choose any fan speed TO USE THE ENERGY SAVER FEATURE YOU WILL SEE DO THIS PRESS MODE BUTTON CHOOSE ENERGY SAVER NOTE In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature at which time the compressor NOTE Fan starts at High Speed ...

Page 8: ...led at any time during operation by again pressing the Sleep button CHECK FILTER FEATURE YOU WILL SEE NOTE This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check NOTE For Delay Stop the unit must be in the ON position LIGHT ON LIGHT ON LIGHT O...

Page 9: ...cuit breaker tripping The fan will continue to run during this time The control will maintain the set temperature within 2 F between 60 F and 90 F degrees The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other and back press and hold the TEMP TIMER Up and Down buttons together for 3 seconds YOU WILL SEE 9 familiar with Fresh Air V...

Page 10: ...dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaner wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditione...

Page 11: ...ESET button Reset to a lower temperature Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Vent set at OPEN position Set vent at CLOSED position for maximum cooling Air direction louvers positioned improperly Position louvers for better air distribution Front of unit is blocked by drapes blinds furniture etc restricts ...