background image

12

Air conditioner will not operate.

Air from unit does not feel cold
enough.

Air conditioner cooling, but room is
too warm - ice forming on cooling
coil behind decorative front.

Air conditioner cooling, but room is
too warm - NO ice forming on
cooling coil behind decorative front.

Air conditioner turns on and off
rapidly.

Noise when unit is cooling.

Water dripping INSIDE when unit is
cooling.

Water dripping OUTSIDE when unit
is cooling.

Remote Sensing Deactivating
Prematurely (Some Models).

Room Too Cold.

Avoid Service Checklist

Before calling for service, review this list. It may save you time and expense. This list
includes common occurrences that are not the result of defective workman-ship or
materials in this appliance.

OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

Plug Current Device Tripped. Press the RESET button.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Control is OFF. Turn Control ON and set to desired setting.

Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 60°F (16°C).

Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.

Reset to a Lower temperature.

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart
when set in the COOL mode.

Outdoor temperature below 60°F (18°C). To defrost the coil, set FAN ONLY Mode.

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode.

Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Tem-
perature to a Higher setting.

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

Temperature is set too High. Set temperature to a Lower setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.

Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc.

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and
furniture.

Dirty air filter - air restricted. Clean air filter.

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air past cooling coils more
frequently.

Air movement sound. This is normal. If too loud, set to a slower FAN setting.

Window vibration - poor installation. Refer to installation instructions or check with installer.

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation
instructions - check with installer.

Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.

Remote control not located within range. Place remote control within 20 feet & 180°, radius of the front of the

unit.

Remote control signal obstructed. Remove obstruction.

Set temperature too low. Increase set temperature.

Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote
control or deactivate remote sensing.

If These Solutions Fail, Call 1-800-444-4944 For Frigidaire Service.

Summary of Contents for 66121617

Page 1: ...E CARE MANUAL provides specific operating instructions for your model Use the room air conditioner only as instructed in this USE CARE MANUAL instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operating and maintaining any appliance USE CARE MANUAL READ AND SAVE THESE INSTRUCTIONS P N 66121617 MEDIANa...

Page 2: ...icers or external causes such as abuse misuse inadequate power supply or acts of God 4 Products with original serial numbers that have been removed or altered and cannot be readily determined Keep your bill of sale delivery slip or some other appropriate payment record The date on the bill establishes the warranty period should service be required If service is performed it is in your best interes...

Page 3: ...t installation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitti...

Page 4: ... is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with out...

Page 5: ...h the remote TOUCH PAD AUTO TEMP DISPLAYS TEMPERATURE TIME FAN SPEED SETS MODE TURNS UNIT ON OR OFF SETS FAN SPEED ADJUSTS TEMP TIME ACTIVATES TIMER FEATURE CHECK FILTER RESET BUTTON CLEAN AIR FEATURE some models SLEEP MODE ADJUSTS TEMP TIME SETS SETS ON OFF LIGHT FAN SPEED SETS MODE ACTIVATE TIMER AUTO TEMP REMOTE CONTROL FOR HEAT MODELS Fig A ON OFF LIGHT FAN SPEED SETS MODE ACTIVATE TIMER AUTO ...

Page 6: ...t speed as the room returns to the original set temperature cally maintained anywhere between 60o F 16o C and 90o F 32o C for cooling mode The temperature will be automatically maintained anywh Press the Fan Faster button will increase the fan speed from Low LO to Medium ME to High HI The digital display will indicate your chosen speed Press the Fan Slower button will decrease the fan speed from H...

Page 7: ...ol will count down the time remaining until start 8 7 5 7 etc The Delay Start mode automatically selects cooling with maximum Fan Speed The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the con trol will automatically change the display back to the h...

Page 8: ...ollen and impurities from the air To cancel this feature Note In this MODE the set temperature will increase by 2 degrees F 30 minutes after the mode is selected The temperature will then increase by another 2 degrees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the or iginally selected temperature This ends the Sleep MODE and the unit w...

Page 9: ...et temperature will only be displayed on the unit itself The LIGHT on the unit control will pulse to indicate it received the signal The LIGHT on the remote control will pulse each time it sends a signal It will con tinue to send this signal until the feature is deactivated by pressing the remote sensing button If the unit does not receive the remote sensing signal during any 3 minute interval the...

Page 10: ...ttons together for 3 seconds Fresh Air Vent Control On some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Vent Open see Fig 2 3 Exchange air from the room and draws fresh air into the room Vent and Exhaust Open see Fig 3 Fig 1 OFF Fig 2 FRESH AIR Fig 3 VENT AUGER WHEEL The louvers will allow you to direct the a...

Page 11: ...ing around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Energy Saving Ideas Do not block air flow in...

Page 12: ...defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air distribution ...

Reviews: