background image

Air Conditioner Features

TIMER: DELAY STOP/START FEATURE:

CHECK FILTER FEATURE:

(continued)

8

YOU WILL SEE HOW MUCH TIME IS CHOSEN:

LIGHT On

YOU WILL SEE:

LIGHT On

DO THIS:

THEN DO THIS:

PRESS TIMER

BUTTON

PRESS UP (     ) OR

DOWN (     ) BUTTON

Note: For Delay Stop, the unit must be in the On position.
Note: For Delay Start, the unit must be in the Off position.
To adjust timer setting, tap or hold the UP arrow(   ) DOWN arrow(   )

to change delay timer at .5 hour increments, up to 10 hours, then

at 1 hour increments up to 24 hours. The control will count down

the time remaining until start (8, 7.5, 7, etc.). The Delay Start mode

automatically  selects  cooling  with  maximum  Fan  Speed.  The

temperature maintained will be the same as previously set. To

change  the  set  temperature,  press  “  COOL”  then  Up  or  Down

arrows until the desired temperature is indicated on the display.

After 5 seconds, the control will automatically change the display

back to the hours remaining until the unit will start/stop. Turning

the unit “ON” or “OFF”  at any time will cancel the Delay Start/ 

Stop function.

The Delay Start/Stop Feature will work until the unit either starts

or stops. Once that happens the above steps have to be repeated

again.

Note: This feature is a reminder to clean the Air Filter (See Care

and Cleaning) for more efficient operation and cooling. The LED

(light) will illuminate after 250 hours of operation. To reset after

cleaning the filter, press the “ Check Filter ” button and the light

will go off.

FAULT CODES

If the display reads “AS”, a sensor
has failed. Contact your Authorized
Frigidaire Service Center

If the display reads “ES”, a sensor
has failed. Contact your Authorized
Frigidaire Service Center

Summary of Contents for 66121613

Page 1: ...Energy Saving Ideas 11 Avoid Service Checklist Contents 3 Packaging NOTE This USE CARE MANUAL pro vides specific operating instructions for your model Use the room air conditioner only as instructed in this USE CARE MANUAL These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operat ing and maintai...

Page 2: ...servicers or external causes such as abuse misuse inadequate power supply or acts of God 4 Products with original serial numbers that have been removed or altered and cannot be readily determined Keep your bill of sale delivery slip or some other appropriate payment record The date on the bill establishes the warranty period should service be required If service is performed it is in your best int...

Page 3: ...correct installation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water...

Page 4: ... is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with out...

Page 5: ...uch pad alone or with the remote NOTE The following instructions represent the Touch Pad the same instructions can be used for the Remote Control YOU WILL SEE TO TURN UNIT ON DO THIS PRESS ON OFF BUTTON Exhaust Open Closed SETS MODE ADJUSTS TEMPERATURE OR TIME SETS FAN SPEEDS DISPLAYS TEMPERATURE TIME CHECK FILTER RESET BUTTON TURNS UNIT ON OR OFF ACTIVATES TIMER SETS MODE EXHAUST SELECTOR Auto Te...

Page 6: ...iginal set temperature Press the Fan Speed button to adjust the fan speed manually temperature is seen on the display This temperature will be automatically maintained anywhere between 60 o F 16 o C and 90 o F 32 o C If you want the display to read the actual room temperature See To Operate on Fan Only section on Page 6 The chosen fan speed LED will light up Air Conditioner Features continued TEMP...

Page 7: ...the mode is selected The temperature will then increase by another 2 degrees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep MODE and the unit will continue to operate as originally programmed The Sleep MODE program can be cancelled at any time during operation by pressing Sleep MODE b...

Page 8: ...et temperature press COOL then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the control will automatically change the display back to the hours remaining until the unit will start stop Turning the unit ON or OFF at any time will cancel the Delay Start Stop function The Delay Start Stop Feature will work until the unit either starts or stops Once that ...

Page 9: ...eit or degrees Celsius To convert from one to the other and back press and hold the TEMP TIMER Up and Down buttons together for 3 seconds EXHAUST CONTROL This Exhaust Control allows the air conditioner to either recirculate inside air CLOSED or exhaust air to the outside OPEN The CLOSED position is used when maximum cooling is desired It may also be used for air recirculation without cooling when ...

Page 10: ...n air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton NOTE To prevent rust or electrical connections from being damaged store air conditioner in an upright position and a dry place Care and Cleaning The capacity of the room a...

Page 11: ...0 F 18 C To defrost the coil set FAN ONLY Mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set ...