3-WIRE GROUNDED JUNCTION BOX

Cable from Power Supply

Black 

Wires

Junction 

Box

Cable from appliance

Ground Wire

(Bare or Green Wire)

White Wire

(Neutral)

U.L.-Listed Conduit 

Connector (or CSA listed)

Red

Wires

White Wire

(Neutral)

 In cold weather shipping and storage 

conditions, make sure that oven is in final location 
at least three (3) hours before switching on power. 
Switching on power while oven is still cold may damage 
the oven controls.

3. Electrical connection

It is the responsibility and obligation of the consumer to 
contact a qualified installer to assure that the electrical 
installation is adequate and is in conformance with the 
National Electrical Code ANSI/NFPA No. 70-latest edition, 
or with CSA Standard C22.1, Canadian Electrical Code, 
Part 1, and local codes and ordinances.

 

Risk of electrical shock  (Failure to 

heed this warning may result in electrocution or 
other serious injury.) This appliance is equipped 
with copper lead wire. If connection is made to 
aluminum house wiring, use only connectors that 
are approved for joining copper and aluminum wire 
in accordance with the National Electrical Code 
and local code and ordinances. When installing 
connectors having screws which bear directly on 
the steel and/or aluminum flexible conduit, do no 
tighten screws sufficiently to damage the flexible 
conduit. Do not over bend or excessively distort 
flexible conduit to avoid separation of convolutions 
en exposure of internal wires.

DO NOT ground to a gas supply pipe. DO NOT connect 
to electrical power supply until appliance is permanently 
grounded. Connect the ground wire before turning on 
the power.

 (If your appliance is equipped with a 

white neutral conductor.)
This appliance is manufactured with a white neutral 
power supply and a frame connected copper wire. 
The frame is grounded by connection of grounding 
lead to neutral lead at the termination of the 
conduit, if used in USA, in a new branch circuit 
installation (1996 NEC), mobile home, recreational 
vehicles, where local code do not permit grounding 
trough the neutral (white) wire or in Canada, 
disconnect the white and green lead from each 
other and use ground lead to ground unit in 
accordance with local codes, connect neutral lead 
to branch circuit-neutral conductor in usual manner 
see Figure 4. If your appliance is to be connected 
to a 3 wire grounded junction box (US only), 
where local code permit connecting the appliance-
grounding conductor to the neutral (white) see 
Figure 3.

 

NOTE TO ELECTRICIAN:

 The armored cable leads 

supplied with the appliance are UL-recognized for 
connection to larger gauge household wiring. The 
insulation of the leads is rated at temperatures much 
higher than temperature rating of household wiring. The 
current carrying capacity of the conductor is governed by 
the temperature rating of the insulation around the wire, 
rather than the wire gauge alone.

Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire 
(US Only) (see figure 3): 

1.  Disconnect the power supply.
2.  In the junction box:
  connect appliance and power supply cable wires as 

shown in Figure 3.

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until 

appliance is permanently grounded.

• Disconnect power to the junction box before 

making the electrical connection.

• This appliance must be connected to a grounded, 

m e t a l l i c ,   p e r m a n e n t   w i r i n g   s y s t e m ,   o r   a 
grounding connector should be connected to 
the grounding terminal or wire lead on the 
appliance.

• Do not use a gas supply line for grounding the 

appliance.
Failure to do any of the above could result in a 

fire, personal injury or electrical shock.

Summary of Contents for 318201533

Page 1: ... These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire 2 5 cm Wide Wood Spacer if Needed NOTES 1 Base must be capable of supporting 225 pounds 102 kg 2 Allow at least 21 53 3 cm clearance in front of oven for door depth when it is open 3 Dimension G cutout depth is critical to the proper installation of t...

Page 2: ...idual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage Table A Appliance Rating Watts 240V Protection Circuit Recommended Appliance Rating Watts 208V Protection Circuit Recommended Less than 4800W 20A...

Page 3: ...s manufactured with a white neutral power supply and a frame connected copper wire The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit if used in USA in a new branch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lea...

Page 4: ...supply 2 Separate the green or bare copper and white appliance cable wires 3 In the junction box connect appliance and power supply cable wires as shown in Figure 4 Figure 4 4 WIRE GROUNDED JUNCTION BOX Cable from Power Supply White Wire Junction Box Cable from appliance White Wire Black Wires Red Wires Ground Wire Ground Wire Bare or Green Wire U L Listed Conduit Connector or CSA listed Figure 5 ...

Page 5: ... the door is open The anti tip mounting screws supplied with the wall oven must be installed to prevent tipping of the wall oven and injury to persons A The mounting holes in the side trims may be used as a template to locate the appliance mounting screw holes see figure 6 B Use the two screws supplied to fix the appliance to the cabinet 7 Install the Bottom Trim Place the top of the bottom trim o...

Page 6: ...l for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to your Use and Care Guide for service phone numbers 5 Leveling the Wall Oven 1 Install an oven rack in the center of the upper oven see Figure 8 2 Place a level on t...

Page 7: ...no debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio Espaciador de Madera de 2 5 cm de ancho si es necesario NOTAS 1 La base debe poder sostener 255 libras 102kg 2 Deje por lo menos 21 53 3 cm de espacio libre para la profundidad de la puerta cuando esta abierta 3 La dimensión G profundidad del corte está primordial para i...

Page 8: ...stico y conectarse a un circuito individual correctamente puesto a tierra protegido por un interruptor o un fusible Para conocer el interruptor o fusible que requiere su modelo vea la placa serial para encontrar la consumación del vatiaje y refierase al cuadro A para encontrar el amperaje del interruptor o fusible Table A Grados de Vatios del electrodoméstico 240V Se recomienda una protección al c...

Page 9: ... alambre de cobre conectado al armazón El armazón esta puesto a tierra por un enlace de la conexión a tierra con la conexión del neutro al final de la línea eléctrica si es usado en los estados unidos una nueva instalación de circuito de bifurcación 1996 NEC casa rodante vehículos recreacionales o donde los códigos locales no permitan poner a tierra mediante el neutro blanco o en Canadá desconecta...

Page 10: ...anco Alambre rojos Alambre negros Alambre blanco Ubicación del número de modelo y de serie La placa con el número de serie está ubicada en la guarnición interior lateral del horno y se puede ver cuando se abre la puerta Cuando haga pedidos de repuestos o solicite información con respecto a su horno esté siempre seguro de incluir el número de modelo y de serie y el número o letra del lote de la pla...

Page 11: ... guía para localizar los tornillos de montado de la unidad figura 6 B Use los dos tornillos proporcionados para colocar la unidad en la cabina tornillos de montado Figura 6 7 Instalación de la Guarnición Inferior Colocar la parte superior de la guarnición inferior sobre las lengüetas laterales del horno debajo de la puerta del horno y fijarlas usando los 2 tornillos provistos con los orificios de ...

Page 12: ...nual del Usuario Esto le podrá ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricación de este artefacto Lea la garantía y la información sobre el servicio en su Manual del Usuario para obtener el número de teléfono gratuito y la dirección del servicio 6 Asegúrese de que el horno de pared está a nivel 1 Instale una rejilla al c...

Reviews: