background image

   

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Grounding type wall
receptacle

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Energy Saving Ideas

Important Safety
Instructions

The power supply cord with

this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired it must be
replaced with a cord from the Product
Manufacturer.

4

Read all instructions before using this air conditioner.

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen.
• If the air conditioner is to be installed in a window, you will probably want to clean both

sides of the glass first. If the window is a triple-track type with a screen panel included, you
may want to remove the screen completely before installation.

• Be sure the air conditioner has been securely and correctly installed according to the

separate installation instructions provided with this manual. Save this manual and installation
instructions for possible future use in removing or reinstalling this unit.

• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on rear

coil.

Electrical Information

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,

proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall

receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.

• Do not run air conditioner with outside protective cover in place. This could result in

mechanical damage within the air conditioner.

• Do not use an extension cord or an adapter plug.

• The capacity of the room air conditioner must fit the room size for efficient and satisfactory

operation.

• Install the room air conditioner on the shady side of your home. A window that faces north

is best because it is shaded most of the day.

• Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs,

enclosures, or other buildings.

• Close the fireplace damper, floor and wall registers so cool air does not escape up the

chimney and into the duct work.

• Keep blinds and drapes in other windows closed during the sunniest part of the day.
• Clean the air filter as recommended in the section “Care and Cleaning.”
• Proper insulation and weather stripping in your home will help keep warm air out and cool

air in.

• External house shading with trees, plants or awnings will help reduce the air conditioner’s

work load.

• Operate heat producing appliances such as ranges, washers, dryers and dishwashers

during the coolest part of the day.

SZ000355(En)-JiXie(3)

10/25/2004, 5:44 PM

4

Summary of Contents for 220204d031

Page 1: ...USE CARE MANUAL AIR CONDITIONER ...

Page 2: ...t of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not ...

Page 3: ...ODUCT REGISTRATION CARD should be filled in completely signed and returned to the Frigidaire Company 2 Warranty 3 Product Registration 3 Normal Sounds 4 Important Safety Instructions 4 Energy Saving Ideas 5 Using Air Conditioner 5 6 Air Conditioner Features 7 Care and Cleaning 8 Avoid Service Checklist Vibration Unit may vibrate and make noise because of poor wall or window construction or incorre...

Page 4: ...e air conditioner be careful to avoid cuts from sharp metal fins on rear coil Electrical Information The complete electrical rating of your new room air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped wi...

Page 5: ...thermostat is used to set the desired room temperature when the unit is being operated in the COOL MODE To set the desired room temperature rotate the thermostat switch to the desired setting After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature Rotate the thermostat selector clockwise for higher cool ...

Page 6: ...vers until the desired Up Down direction is obtained 6 ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you should become familiar with Figure 1 VENT CLOSED Figure 2 VENT OPEN Figure 3 VENT EXHAUST OPEN Fresh Air Vent Control On some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent ...

Page 7: ...thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish o...

Page 8: ...uching cold coil located behind air filter Straighten tube away from coil Outdoor temperature below 70 F 21 C To defrost the coil set selector to FAN position Then set thermostat to warmer position Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set selector to FAN Thermostat set too cold for night time cooling To defrost the coil set selector to a FAN position T...

Reviews: