background image

Important Safety Instructions

 - RISK OF FIRE - 

Read all of the following instructions before installing and using this appliance:

Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered with 

• 

rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Place all materials in a garbage 
container or make materials inaccessible to children.

Clothes dryer installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.

• 

Install the clothes dryer according to the manufacturer’s instructions and local codes.

• 

The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National 

• 

Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code C22.1 part 1.

The gas service to the dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas 

• 

Code ANSI Z223.1, or in Canada, CAN/ACG  B149.1-2000.

The dryer is designed under ANSI Z 21.5.1  or ANSI/UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for HOME USE 

• 

only. This dryer is not recommended for commercial applications such as restaurants, beauty salons, etc.

Do not install a clothes dryer with fl exible plastic venting material. Flexible venting materials are known to collapse, be eas-

• 

ily crushed and trap lint. These conditions will obstruct clothes dryer airfl ow and increase the risk of fi re.

The instructions in this manual and all other literature included with this dryer are not meant to cover every possible 

• 

condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and 
maintaining any appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use any phone in your building.

• 

Clear the room, building or area of all occupants.

• 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• 

If you cannot reach your gas supplier, call the fi re department.

• 

Save these instructions for future reference.

Pre-Installation Requirements

 For your safety the information in this manual must be followed to minimize the risk of fi re or explosion or to 

prevent property damage, personal injury or loss of life. Do not store or use gasoline or other fl ammable vapors and liquids in 
the vicinity of this or any other appliance.

2

Important Safety Instructions ................................................2
Pre-installation Requirements ................................................2
Installation Requirements .................................................. 3-7
Installed Dimensions .............................................................8

Installation Instructions ................................................... 9-13
Reversing door .............................................................. 14-15
Accessories/Replacement parts ............................................16
Español ...............................................................................17

Tools and materials needed for installation:

Adjustable pliers

• 

Phillips, straight, & square bit screw-

• 

drivers
Adjustable wrench

• 

Pipe wrench for gas supply (gas dryer)

• 

LP-resistant thread tape (for natural 

• 

gas or LP supply, gas dryer)

Carpenter’s level

• 

External vent hood

• 

4-inch (10.2 cm), rigid metal or semi-

• 

rigid metal exhaust duct work
3-wire or 4-wire 240 volt cord kit 

• 

(electric dryer)
4 in. (10.2 cm) clamp

• 

Gas line shutoff valve (gas dryer)

• 

½ NPT union fl are adapters (x2) and 

• 

fl exible gas supply line (gas dryer)
Metal foil tape (not duct tape)

• 

Table of Contents

Recognize safety symbols, words and labels

Safety items throughout this manual are labeled with a 
WARNING or CAUTION based on the risk type as described:

 This symbol alerts you to situations that 

may cause serious body harm, death or property damage.

 This symbol alerts you to situations that may 

cause bodily injury or property damage.

Summary of Contents for 137111500B

Page 1: ...www frigidaire com P N 137111500B 0903 Installation Instructions Gas Electric Dryer Instrucciones de Instalación Secadora a Gas y Eléctrica ...

Page 2: ...en installing operating and maintaining any appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department S...

Page 3: ...ORD KIT not supplied The dryer MUST employ a 4 conductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers For 4 wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 4 WIRE SYSTEM Electrical requirements for gas dryer CIRC...

Page 4: ... be constructed of stainless steel or plastic coated brass 4 The gas supply line MUST have an individual shutoff valve 5 A 1 8 inch 0 32 cm N P T plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dryer 6 The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping ...

Page 5: ...be exhausted outdoors Do not exhaust dryer into a chimney a wall a ceiling an attic a crawl space or any concealed space of a building A clothes dryer produces combustible lint If the dryer is not exhausted outdoors some fine lint will be expelled into the laundry area An accumulation of lint in any area of the home can create a health and fire hazard FIRE HAZARD Exceeding the length of duct pipe ...

Page 6: ...ed and cleaned a minimum of every 18 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation Manufactured or mobile home installation Installation MUST conform to current Manufactured 1 Home Construction Safety Standard Title 24 CFR Part 32 80 formerly the Federal Standard for Mobile Home Construction and Safety Titl...

Page 7: ...is installed A louvered door with equivalent air openings for the full length of the door is acceptable closet door F or other than straight back venting a quick turn 90 dryer vent elbow vented right or down in free standing dryer or right on pedestal mounted dryer must be installed to achieve 0 0 cm installation EXPLOSION HAZARD Do not install the dryer where gasoline or other flammables are kept...

Page 8: ... on pedestal mounted or freestanding dryer adds approximately 3 75 in 9 5 cm to installation depth Downward venting of exhaust on pedestal mounted dryer adds approximately 2 25 in 5 7 cm to installation depth To obtain these minimal depth dimensions dryer must be vented straight back Using a quick turn 90 elbow right adds approximately 0 75 in 2 cm to installation depth Upward venting of exhaust o...

Page 9: ...d aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired recep tacle Dryers operating on 208 volt power supply will have longer drying times than dryers operating on 240 volt power supply ELECTRICAL SHOCK HAZARD Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed ...

Page 10: ...k of the dryer Use a 1 2 inch to 3 8 inch 1 27 cm to 0 96 cm reducer for the connection Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections Open the shutoff valve in the gas supply line to allow gas 3 to flow through the pipe Wait a few minutes for gas to move through the gas line All connections must be wrench tightened Flare Union ...

Page 11: ...here strain relief here Terminal screw Terminal screw recovery slot recovery slot Line 1 Line 1 BRASS terminal BRASS terminal Neutral Neutral SILVER terminal SILVER terminal Line 2 Line 2 BRASS terminal BRASS terminal Access cover Access cover screw screw Terminal Terminal block block Neutral Neutral center wire center wire 30 AMP 30 AMP NEMA 10 30 NEMA 10 30 Follow manufacturer s guidelines for f...

Page 12: ...ternal ground GREEN screw GREEN screw Install Install UL approved UL approved strain relief here strain relief here Terminal screw Terminal screw recovery slot recovery slot Line 1 Line 1 BRASS terminal BRASS terminal Neutral Neutral SILVER terminal SILVER terminal Line 2 Line 2 BRASS terminal BRASS terminal Access cover Access cover screw screw Terminal Terminal block block Neutral Neutral WHITE ...

Page 13: ...resting solidly on all four legs Place a level on top of the dryer The dryer MUST be level and resting solidly on all four legs Rock alternating corners to check for stability Remove and discard door tape Plug the power cord into a grounded outlet 3 Turn on the power at the circuit breaker fuse box 4 Read the 5 Use Care Guide provided with the dryer It contains valuable and helpful information tha...

Page 14: ...to hinge front panel or door After the remaining screws are loosened continue to remove all Figure 3 3 Place door on a towel or pad handle side down to prevent any possible scratches to door Remove all remaining four 4 screws between hinge and door Figure 3 4 Remove four 4 screws from side of door opposite of where hinge was mounted Figure 4 5 Remove two 2 door handle screws and two 2 hole plugs f...

Page 15: ... 14 Install four 4 screws into holes that had secured the hinge 15 Remove striker and discard 16 Remove square plug and reinstall in hole striker was just removed 17 Install striker included in literature bag into hole square plug was previously installed Figure 12 18 Reinstall door handle by placing the handle mounting bosses through holes in lens and transition ring and installing screws through...

Page 16: ...lude a stacking kit or you desire another stacking kit you may order one LP CONVERSION KIT P N PCK4200 Gas dryers intended for use in a location supplied with LP must use a conversion kit prior to installation MOBILE HOME INSTALLATION KIT P N 137067200 Installations in mobile homes require use of MOBILE HOME INSTALLATION KIT DRYING RACK P N 137067300 Depending on the model you purchased a drying r...

Page 17: ...i dado y hacer uso de buenas prácticas de seguridad QUÉ HACER SI SIENTE OLOR A GAS No intente encender ningún electrodoméstico No toque ningún interruptor eléctrico no utilice ningún teléfono en la vivienda Despeje la habitación el edificio o el área de todos los ocupantes Llame inmediatamente a su proveedor de gas desde el teléfono de un vecino Siga las instrucciones del proveedor de gas Si no pu...

Page 18: ...CA TETRAFILAR no incluido La secadora DEBE emplear un cable de alimentación eléctrica de 4 conductores tipo NEMA 14 30 SRDT o ST según se especifique calificado para CA mínima de 240 voltios 30 amp con 4 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y calificados para uso en secadoras de ropa Para obtener instrucciones sobre la conexión tetrafilar consulte ...

Page 19: ...ble para conectar la secadora a la línea de suministro de gas La tubería DEBE ser de acero inoxidable o de latón plastificado 4 La línea de suministro de gas DEBE tener una válvula de cierre individual 5 Se DEBE instalar una derivación N P T de 0 32 cm 1 8 pulgadas con tapón roscado que permita conectar un medidor de prueba inmediatamente después de la conexión de suministro de gas a la secadora e...

Page 20: ...da del conducto al exterior utilice una capucha de ven tilación aprobada y selle todas las uniones con cinta para conductos Todos los accesorios macho para tubos DEBEN instalarse teniendo en cuenta el flujo de aire PELIGRO DE INCENDIO Una seca dora de ropa debe tener ventilación al exterior No ventile la secadora a una chimenea pared techo ático pasajes entre pisos ni ningún espacio oculto de la v...

Page 21: ...a menudo deberá comprobar que el sistema de escape y la capucha de ventilación funcionan correctamente Instalación en una casa rodante La instalación DEBE cumplir con la actual Norma de 1 Seguridad y Construcción de Casas Rodantes título 24 CFR Parte 32 80 que anteriormente se conocía como la Norma Federal de Seguridad y Construcción de Casas Rodantes Federal Standard for Mobile Home Construction ...

Page 22: ...se alma cene gasolina u otros productos inflamables Si la secadora se instala en un garaje debe estar a una altura mínima de 45 7 cm 18 pulgadas por encima del suelo De lo contrario podría producirse una explosión un incendio quemaduras o incluso la muerte NO INSTALE LA SECADORA En una zona expuesta a la humedad o a las condiciones 1 climáticas externas En un área en la que esté en contacto con co...

Page 23: ... gas altura de la línea central para ventilación trasera suministro eléctrico en la parte trasera de la unidad secadora independiente sobre el piso línea del piso línea del piso secadora colocada sobre pedestal opcional Para obtener estas dimensiones mínimas de profundidad la secadora debe ser ventilada derecho hacia atrás Si se usa un codo de 90 hacia la derecha se agregan aproximadamente 0 75 2 ...

Page 24: ...icos El receptáculo y el cableado correcto consiste en un cable de alimentación con alambres de cobre con un receptá culo de cables de cobre Las secadoras que funcionan con 208 voltios de co rriente eléctrica tendrán tiempos de secado más prolongados que las que funcionan con 240 voltios de corriente eléctrica PELIGRO DE DESCARGA ELÉCTRICA Una conexión incorrecta del conductor de conexión a tierra...

Page 25: ...e permita la facilidad de apertura y cierre No bloquee el acceso a la válvula de cierre de gas NO conecte la secadora al servicio de gas LP sin convertir la válvula de gas El kit de conversión a gas LP debe ser instalado por un técnico calificado Tom Tomacorriente con acorriente con puesta a tierr puesta a tierra ninguna circunstancia ninguna circunstancia No corte retire ni No corte retire ni des...

Page 26: ...O DE DESCARGA ELÉCTRICA El no desconectar el suministro eléctrico antes de realizar cualquier reparación puede ocasionar lesiones personales o incluso la muerte PELIGRO DE DESCARGA ELÉCTRICA No forme un ángulo agudo con el cableado conductor ni los doble en el punto de conexión Para mover la secadora desde un sistema tetrafilar e instalarla en un sistema trifilar mueva la conexión a tierra interna...

Page 27: ...conexión a tierra 7 que integra el enchufe preformado de la secadora al bloque terminal y conéctelo junto con el conductor neutro BLANCO del cable de alimentación al terminal PLATEADO del centro del bloque terminal Ajuste el tornillo con firmeza Conecte los conductores ROJO y NEGRO del cable de 8 alimentación a los terminales externos de color LATÓN del bloque terminal Ajuste los dos tornillos con...

Page 28: ...co fusibles Consulte la Guía de uso y cuidado que se proporciona con 5 la secadora Dicha guía contiene información útil y valiosa que le ahorrará tiempo y dinero Si tiene alguna pregunta durante el funcionamiento inicial 6 repase la Lista de control para evitar el servicio técnico de su Guía de uso y cuidado antes de llamar al servicio técnico Guarde estas instrucciones cerca de la secadora para 7...

Page 29: ...un dan o a la bisagra al Panel o a la Puerta Despues de aflojar los tornillos restantes proceda a quitarlos completamente 3 Coloque la Puerta con el lado de la bisagra hacia abajo sobre una toalla o colchoneta para evitar que se raye Quite los cuatro 4 tornillos restantes entre la bisagra y la puerta Figura 3 4 Quite cuatro 4 tornillos del lado contrario de la puerta donde estaba montada la bisagr...

Page 30: ... correcta 14 Instale cuatro 4 tornillos en los agujeros que sujetaban la bisagra 15 Quite la contra y deseche 16 Quite el tapon cuadrado y reinstálese en el agujero donde estaba la contra 17 Instale la contra mismo que se proporciona en la bolsa de la Literatura en el agujero cuadrado en donde quito el tapon 18 Re instale la manija de la Puerta haciendo pasar los pernos de montaje de la misma a tr...

Page 31: ...gregará aproximadamente 38 cm 15 pulgadas a la altura de su unidad para una altura total de 130 cm 51 25 pulgadas KIT DE SECADORA PARA CENTRO DE LAVADO Pieza No 134700600 Dependiendo del modelo que haya comprado es posible que esta secadora incluya un kit para instalarla sobre la lavadora correspondiente Si el modelo que adquirió no incluye un kit de instalación sobre la lavadora o desea un kit di...

Page 32: ......